Suppr超能文献

溶剂和再湿润时间对牙本质黏附的影响。

Effect of solvent and rewetting time on dentin adhesion.

作者信息

Perdigão J, Frankenberger R

机构信息

Division of Operative Dentistry, Department of Restorative Sciences, Minnesota Dental Research Center for Biomaterials and Biomechanics, University of Minnesota, Minneapolis, USA.

出版信息

Quintessence Int. 2001 May;32(5):385-90.

Abstract

OBJECTIVE

The purpose of this in vitro study was to determine the influence of solvent and rewetting time on microtensile dentin bond strengths of four dentin adhesives.

METHOD AND MATERIALS

Sixty human molar specimens were divided into four dentin adhesive treatment groups: (1) a water-based total-etch dentin adhesive, EBS Multi; (2) an ethanol-based total-etch adhesive, Excite; (3) an acetone-based total-etch adhesive, Prime & Bond NT; and (4) an ethanol- and water-based total-etch adhesive, Single Bond. For each dentin adhesive, three specimens were assigned to five dentin moisture conditions. Specimens were tested in the tensile mode.

RESULTS

When adhesives were applied to moist dentin, bond strengths varied from 26.2 MPa for Prime & Bond NT to 29.5 MPa for Single Bond without any statistical differences. When applied to dentin that had been dried for 15 seconds, Prime & Bond NT and Excite resulted in the lowest mean bond strengths, but they were statistically similar to each other (7.9 and 8.3 MPa, respectively). Single Bond resulted in a mean bond strength of 12.7 MPa, which was significantly lower than that of EBS Multi (24.1 MPa). For the latter, all mean bond strengths were statistically similar when some amount of moisture was present on the surface. For the other three adhesives, mean bond strengths returned to the range obtained on moist dentin only when dentin was rewet for 30 seconds.

CONCLUSION

Bond strengths upon rewetting depend on the type of solvent in the bonding system, and rewetting time.

摘要

目的

本体外研究的目的是确定溶剂和再湿润时间对四种牙本质粘结剂微拉伸牙本质粘结强度的影响。

方法和材料

60颗人类磨牙标本被分为四个牙本质粘结剂治疗组:(1)一种水基全蚀刻牙本质粘结剂,EBS Multi;(2)一种乙醇基全蚀刻粘结剂,Excite;(3)一种丙酮基全蚀刻粘结剂,Prime & Bond NT;以及(4)一种乙醇和水基全蚀刻粘结剂,Single Bond。对于每种牙本质粘结剂,三个标本被分配到五种牙本质湿度条件下。标本在拉伸模式下进行测试。

结果

当粘结剂应用于湿润牙本质时,粘结强度从Prime & Bond NT的26.2MPa到Single Bond的29.5MPa不等,没有任何统计学差异。当应用于干燥15秒的牙本质时,Prime & Bond NT和Excite的平均粘结强度最低,但它们在统计学上彼此相似(分别为7.9MPa和8.3MPa)。Single Bond的平均粘结强度为12.7MPa,明显低于EBS Multi(24.1MPa)。对于后者,当表面存在一定量的水分时,所有平均粘结强度在统计学上相似。对于其他三种粘结剂,只有当牙本质再湿润30秒时,平均粘结强度才恢复到在湿润牙本质上获得的范围。

结论

再湿润后的粘结强度取决于粘结系统中溶剂的类型和再湿润时间。