Suppr超能文献

关节镜手术中堆叠半结的优化。

Optimization of stacked half-hitch knots for arthroscopic surgery.

作者信息

Chan K C, Burkhart S S, Thiagarajan P, Goh J C

机构信息

Department of Orthopaedic Surgery, National University Hospital, National University of Singapore, Republic of Singapore.

出版信息

Arthroscopy. 2001 Sep;17(7):752-9. doi: 10.1053/jars.2001.25329.

Abstract

PURPOSE

This study was conducted to determine the optimal configuration of stacked half-hitch knots that would give the maximum knot-holding capacity (KHC).

TYPE OF STUDY

Mechanical testing study.

METHODS

The 2 types of suture materials tested were No. 1 PDS II monofilament and No. 2 Ethibond braided (Ethicon, Somerville, NJ) because these are the 2 most commonly used sutures in arthroscopic surgery. Twelve configurations of stacked half-hitch knots including 2 versions of the Revo knot were tested. Knots were tied between 2 steel hooks 7 mm apart on a manual knot-testing machine. The steel hooks were spread apart to break the knot and the KHC was determined by the peak load recorded on the digital force transducer. Maximum KHC was achieved for No. 1 PDS II sutures by locking the knot with 2 RHAPs (reversing half-hitch on alternate post) and, for No. 2 Ethibond sutures, by locking the knot with 3 RHAPs. Because of the possibility of PDS II sutures unraveling, it is recommended for both No. 1 PDS II and No. 2 Ethibond sutures, that all stacked half-hitches be locked with 3 RHAPs. By adding 1 RHAP to the Revo knot, failure by slippage can be eliminated.

RESULTS

The recommended knots tied with braided No. 2 Ethibond sutures were 1.5 times stronger than knots tied with No. 1 PDS II sutures. Although there was variability in the KHC of the recommended knots tied by different surgeons using different knot tiers, the greatest difference in the mean KHC was less than 10%.

CONCLUSIONS

Stacked half-hitch knots locked with 3 RHAPs are unlikely to fail by slippage.

摘要

目的

本研究旨在确定能提供最大结持力(KHC)的堆叠半结的最佳构型。

研究类型

力学测试研究。

方法

测试的两种缝合材料为1号PDS II单丝缝线和2号Ethibond编织线(Ethicon公司,新泽西州萨默维尔),因为这是关节镜手术中最常用的两种缝线。测试了12种堆叠半结的构型,包括2种版本的Revo结。在手动打结试验机上,将结系在相距7毫米的两个钢钩之间。将钢钩拉开以解开结,并通过数字力传感器记录的峰值载荷确定KHC。对于1号PDS II缝线,通过用2个反向交替半结(RHAP)锁定结可实现最大KHC;对于2号Ethibond缝线,通过用3个RHAP锁定结可实现最大KHC。由于PDS II缝线有松开的可能性,建议对于1号PDS II和2号Ethibond缝线,所有堆叠半结都用3个RHAP锁定。通过在Revo结上增加1个RHAP,可以消除因滑动导致的失败。

结果

用2号Ethibond编织缝线系的推荐结比用1号PDS II缝线系的结强1.5倍。尽管不同外科医生使用不同打结层数系的推荐结的KHC存在差异,但平均KHC的最大差异小于10%。

结论

用3个RHAP锁定的堆叠半结不太可能因滑动而失败。