Abstract

90Y-FHMA (Ferric hydroxide macroaggregates) and 90Y-HA (hydroxyapatite) were prepared in >95% yield using 90Y from an in-house 90Sr-90Y generator. Most of the particles ranged from 5 to 20 microm in diameter and retained radiochemical purity > 95% in human serum for at least 7 days at 37 degrees C. Gamma camera imaging of normal rabbits after intraarticulation of the particles showed complete retention of activity within the knee cavity with no measurable radioactivity leaching out of the joints over a 96 hour period.

摘要

使用内部90Sr-90Y发生器产生的90Y制备了90Y-氢氧化铁大颗粒(Ferric hydroxide macroaggregates,90Y-FHMA)和90Y-羟基磷灰石(hydroxyapatite,90Y-HA),产率>95%。大多数颗粒直径在5至20微米之间,在37摄氏度的人血清中,其放射化学纯度在至少7天内保持>95%。对正常兔子关节内注射颗粒后进行γ相机成像,结果显示膝关节腔内的活性完全保留,在96小时内关节没有可测量的放射性物质渗出。