Horizontal eye movements of the alert rhesus monkey resulting from both pseudorandom binary sequence (PRBS) and single frequency sinusoidal rotational stimulation were analyzed using a PDP 11/40 computer in order to generate gain, phase, and coherence estimates at discrete frequencies between 0.008 and 1.28 Hz. A computer simulation of vestibular induced eye movements was used to validate our analysis procedures and to determine the effects of digital noise. Frequency domain transfer functions derived from gain and phase estimates revealed that the responses to PRBS stimulation and to single frequency sinusoids were not appreciably different. PRBS testing was accomplished in approximately one third the time required for sinusoidal testing and yielded highly reproducible data. We conclude that PRBS stimulation is a reliable and efficient method for assessing linear system parameters of the horizontal vestibulo-ocular reflex. PRBS testing may be particularly advantageous in studies of vestibulo-oculomotor plasticity in which rapid assessment of alterations in system dynamics is essential.

摘要

为了在0.008至1.28Hz的离散频率下生成增益、相位和相干估计值,使用PDP 11/40计算机分析了警觉恒河猴在伪随机二进制序列(PRBS)和单频正弦旋转刺激下的水平眼动。利用前庭诱发眼动的计算机模拟来验证我们的分析程序,并确定数字噪声的影响。从增益和相位估计中得出的频域传递函数表明,对PRBS刺激和单频正弦波的反应没有明显差异。PRBS测试所需时间约为正弦测试的三分之一,并产生了高度可重复的数据。我们得出结论,PRBS刺激是评估水平前庭眼反射线性系统参数的一种可靠且有效的方法。在研究前庭眼动可塑性时,PRBS测试可能特别有利,因为在这些研究中,快速评估系统动力学的变化至关重要。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验