Suppr超能文献

使用伪随机二进制序列和单频正弦刺激,将线性系统分析应用于警觉恒河猴的水平前庭眼反射。

Application of linear system analysis to the horizontal vestibulo-ocular reflex of the alert rhesus monkey using pseudorandom binary sequence and single frequency sinusoidal stimulation.

作者信息

Furman J M, O'Leary D P, Wolfe J W

出版信息

Biol Cybern. 1979 Aug 1;33(3):159-65. doi: 10.1007/BF00337294.

Abstract

Horizontal eye movements of the alert rhesus monkey resulting from both pseudorandom binary sequence (PRBS) and single frequency sinusoidal rotational stimulation were analyzed using a PDP 11/40 computer in order to generate gain, phase, and coherence estimates at discrete frequencies between 0.008 and 1.28 Hz. A computer simulation of vestibular induced eye movements was used to validate our analysis procedures and to determine the effects of digital noise. Frequency domain transfer functions derived from gain and phase estimates revealed that the responses to PRBS stimulation and to single frequency sinusoids were not appreciably different. PRBS testing was accomplished in approximately one third the time required for sinusoidal testing and yielded highly reproducible data. We conclude that PRBS stimulation is a reliable and efficient method for assessing linear system parameters of the horizontal vestibulo-ocular reflex. PRBS testing may be particularly advantageous in studies of vestibulo-oculomotor plasticity in which rapid assessment of alterations in system dynamics is essential.

摘要

为了在0.008至1.28Hz的离散频率下生成增益、相位和相干估计值,使用PDP 11/40计算机分析了警觉恒河猴在伪随机二进制序列(PRBS)和单频正弦旋转刺激下的水平眼动。利用前庭诱发眼动的计算机模拟来验证我们的分析程序,并确定数字噪声的影响。从增益和相位估计中得出的频域传递函数表明,对PRBS刺激和单频正弦波的反应没有明显差异。PRBS测试所需时间约为正弦测试的三分之一,并产生了高度可重复的数据。我们得出结论,PRBS刺激是评估水平前庭眼反射线性系统参数的一种可靠且有效的方法。在研究前庭眼动可塑性时,PRBS测试可能特别有利,因为在这些研究中,快速评估系统动力学的变化至关重要。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验