Implications of using high contrast mammography X-ray film-screen combinations.

作者信息

Meeson S, Young K C, Rust A, Wallis M G, Cooke J, Ramsdale M L

机构信息

National Co-ordinating Centre for the Physics of Mammography, Guildford GU2 7XX, UK.

出版信息

Br J Radiol. 2001 Sep;74(885):825-35. doi: 10.1259/bjr.74.885.740825.

Abstract

The objective of this study was to determine the implications of using Fuji AD-M and Kodak min-R 2000, two high contrast X-ray film types developed for mammography. Evaluation of the Fuji AD-M film was divided into two parts. The first part was a contralateral comparison between mammograms using Fuji AD-M and Fuji UM-MA HC film-screen combinations. Fuji AD-M contrast was about 25% higher than that of Fuji UM-MA HC. The effect of increased contrast on image quality was investigated by visually grading the quality of information in different parts of each mammogram. Fuji AD-M film was generally judged to be better for overall diagnosis. However, 2.3% of mammograms produced using Fuji AD-M film were not acceptable and might have led to a technical recall of the patient. In the second part of this study, sets of mammograms from women attending mobile screening units were reviewed. One unit used Fuji AD-M film and the other used Kodak min-R 2000 film. Both samples of mammograms were digitized and analysed. The average film gradients between an optical density (OD) of 0.25 and 2.00 above base plus fog were 4.38 for Fuji AD-M film and 3.77 for Kodak min-R 2000 film. The main breast regions of the mammograms were judged to be satisfactorily displayed when breast tissues were above ODs of approximately 0.6 for Fuji AD-M film and 0.8 for Kodak min-R 2000 film.

摘要

相似文献

1
Implications of using high contrast mammography X-ray film-screen combinations.
Br J Radiol. 2001 Sep;74(885):825-35. doi: 10.1259/bjr.74.885.740825.
2
Image quality and breast dose of 24 screen-film combinations for mammography.
Br J Radiol. 2006 Feb;79(938):123-9. doi: 10.1259/bjr/84646476.
3
Skin edge perception in mammograms: a comparison of two film-screen combinations.
Br J Radiol. 2000 Apr;73(868):370-5. doi: 10.1259/bjr.73.868.10844862.
4
The use of a contrast-detail test object in the optimization of optical density in mammography.
Br J Radiol. 1995 Mar;68(807):277-82. doi: 10.1259/0007-1285-68-807-277.
5
A comparison of two mammography film-screen combinations designed for standard-cycle processing.
Br J Radiol. 1999 Jan;72(853):73-5. doi: 10.1259/bjr.72.853.10341692.
6
A comparison of mammography screen-film combinations.
Radiology. 1992 Sep;184(3):629-34. doi: 10.1148/radiology.184.3.1509043.
7
Effects of processing conditions on mammographic image quality.
Acad Radiol. 1999 Aug;6(8):464-70. doi: 10.1016/s1076-6332(99)80165-2.
8
A comparative study of films and screens for mammography.
Br J Radiol. 1987 Jan;60(709):73-8. doi: 10.1259/0007-1285-60-709-73.
9
New mammography screen/film combinations: imaging characteristics and radiation dose.
AJR Am J Roentgenol. 1990 Apr;154(4):713-9. doi: 10.2214/ajr.154.4.2107663.
10
Short communication: a comparison of fine and medium screens for mammography.
Br J Radiol. 1996 Feb;69(818):182-5. doi: 10.1259/0007-1285-69-818-182.

引用本文的文献

1
An automatic correction method for the heel effect in digitized mammography images.
J Digit Imaging. 2008 Jun;21(2):177-87. doi: 10.1007/s10278-007-9072-1. Epub 2007 Sep 11.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验