Eller F J, King J W
New Crops and Processing Technology Research, National Center for Agricultural Utilization Research, Agricultural Research Service, U.S. Department of Agriculture, 1815 North University Street, Peoria, Illinois 61604, USA.
J Agric Food Chem. 2001 Oct;49(10):4609-14. doi: 10.1021/jf0103370.
This study investigated the supercritical carbon dioxide (SC-CO(2)) extraction of fat from ground beef and the effects of several factors on the gravimetric determination of fat. The use of ethanol modifier with the SC-CO(2) was not necessary for efficient fat extraction; however, the ethanol did increase the coextraction of water. This coextraction of water caused a significant overestimation of gravimetric fat. Oven-drying ground beef samples prior to extraction inhibited the subsequent extraction of fat, whereas oven-drying the extract after collection decreased the subsequent gas chromatographic fatty acid methyl ester (GC-FAME) fat determination. None of the drying agents tested were able to completely prevent the coextraction of water, and silica gel and molecular sieves inhibited the complete extraction of fat. Measurements of collection vial mass indicated that CO(2) extraction/collection causes an initial increase in mass due to the density of CO(2) (relative to displaced air) followed by a decrease in vial mass due to the removal of adsorbed water from the collection vial. Microwave-drying of the empty collection vials removes approximately 3 mg of adsorbed water, approximately 15-20 min is required for readsorption of the displaced water. For collection vials containing collected fat, microwave-drying effectively removed coextracted water, and the vials reached equilibration after approximately 10-15 min. Silanizing collection vials did not significantly affect weight loss during microwave-drying. SC-CO(2) can be used to accurately determine fat gravimetrically for ground beef, and the presented method can also be followed by GC-FAME analysis to provide specific fatty acid information as well.
本研究调查了超临界二氧化碳(SC-CO₂)从碎牛肉中提取脂肪的情况以及几个因素对脂肪重量测定的影响。对于高效的脂肪提取,在SC-CO₂中使用乙醇改性剂并非必要;然而,乙醇确实增加了水的共提取量。这种水的共提取导致重量法测定的脂肪显著高估。在提取前对碎牛肉样品进行烘干会抑制随后的脂肪提取,而在收集后对提取物进行烘干则会降低随后气相色谱脂肪酸甲酯(GC-FAME)法测定脂肪的结果。所测试的干燥剂均不能完全防止水的共提取,并且硅胶和分子筛会抑制脂肪的完全提取。收集瓶质量的测量表明,CO₂提取/收集由于CO₂的密度(相对于被置换的空气)会导致质量最初增加,随后由于从收集瓶中去除吸附水而导致瓶质量下降。对空收集瓶进行微波干燥可去除约3 mg的吸附水,置换水的再吸附大约需要15 - 20分钟。对于装有收集到的脂肪的收集瓶,微波干燥有效地去除了共提取的水,并且瓶在大约10 - 15分钟后达到平衡。硅烷化处理收集瓶对微波干燥过程中的重量损失没有显著影响。SC-CO₂可用于准确地重量法测定碎牛肉中的脂肪,并且所提出的方法之后也可进行GC-FAME分析以提供特定的脂肪酸信息。