Abstract

A new clotting test, the Hepato-Quick, indicated in the study of liver insufficiency was used in 102 patients comprising 22 cases of acute hepatitis, 15 of chronic hepatitis, 21 of cirrhosis of the liver, 11 with liver conditions of various nature, 23 cases with a number of diseases without liver impairment and 10 normal subjects. Quick's test was carried out at the same time in all subjects. Results show that the Hepato-Quick test is more sensitive than Quick's test for identifying liver impairment. The greater sensitivity is statistically significant. The test presents excellent standardization and can be carried out on automatic equipment.

摘要

一种新的凝血试验——肝速凝试验,用于肝功能不全的研究,102例患者参与了该试验,其中包括22例急性肝炎患者、15例慢性肝炎患者、21例肝硬化患者、11例患有各种肝脏疾病的患者、23例患有多种无肝脏损害疾病的患者以及10名正常受试者。所有受试者同时进行奎克试验。结果表明,在识别肝脏损害方面,肝速凝试验比奎克试验更敏感。更高的敏感性具有统计学意义。该试验具有出色的标准化程度,可在自动设备上进行。