A solution-based inductively coupled plasma optical emission spectrometric (ICP-OES) method is described for elemental analysis with relative expanded uncertainties on the order of 0.1% relative. The single-element determinations of 64 different elements are presented, with aggregate performance results for the method and parameters for the determination of each element. The performance observed is superior to that previously reported for ICP-OES, resulting from a suite of technical strategies that exploit the strengths of contemporary spectrometers, address measurement and sample handling noise sources, and permit rugged operation with small uncertainty. Taken together, these strategies constitute high-performance ICP-OES.

摘要

本文描述了一种基于溶液的电感耦合等离子体发射光谱法(ICP-OES),用于元素分析,其相对扩展不确定度约为0.1%。文中给出了64种不同元素的单元素测定结果,以及该方法的总体性能结果和各元素测定参数。所观察到的性能优于先前报道的ICP-OES,这得益于一系列技术策略,这些策略利用了当代光谱仪的优势,解决了测量和样品处理中的噪声源问题,并允许在不确定度较小的情况下进行稳定操作。这些策略共同构成了高性能ICP-OES。