Hughes J G, Vetter E A, Patel R, Schleck C D, Harmsen S, Turgeant L T, Cockerill F R
Division of Clinical Microbiology, Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota 55905, USA.
J Clin Microbiol. 2001 Dec;39(12):4468-71. doi: 10.1128/JCM.39.12.4468-4471.2001.
An evaluation was undertaken to determine the utility of the BACTEC Peds Plus/F bottle and the BACTEC 9240 instrument (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) for the detection of clinically significant microorganisms in synovial fluid specimens. The Peds Plus/F bottle was used because in our laboratory the quantity of synovial fluid available for culture is frequently in the range of 0.5 to 3.0 ml. The culture results obtained with the Peds Plus/F bottle were compared to those obtained by a conventional agar plate method for a total of 805 synovial fluid specimens. Microbial growth was produced by 74 cultures (9.2%) from 60 patients, yielding a total of 77 microorganisms. Organisms were classified as pathogens (n = 62), contaminants (n = 12), or indeterminate (n = 3) on the basis of a review of the patients' medical histories. Culture using BACTEC Peds Plus/F bottle detected statistically significantly more pathogens overall (62 versus 51 pathogens [P = 0.001]) and statistically fewer contaminants overall (1 versus 11 contaminants [P = 0.006]) than culture by the agar plate method. These results indicate the superior performance of the BACTEC Peds Plus/F bottle over the conventional agar plate method for the detection of clinically significant microorganisms from synovial fluid specimens.
进行了一项评估,以确定BACTEC Peds Plus/F瓶和BACTEC 9240仪器(Becton Dickinson诊断仪器系统公司,马里兰州斯帕克斯)在检测滑液标本中具有临床意义的微生物方面的效用。使用Peds Plus/F瓶是因为在我们实验室中,可用于培养的滑液量通常在0.5至3.0毫升范围内。将使用Peds Plus/F瓶获得的培养结果与通过传统琼脂平板法对总共805份滑液标本获得的结果进行比较。60名患者的74份培养物(9.2%)产生了微生物生长,共培养出77种微生物。根据对患者病史的回顾,将微生物分为病原体(n = 62)、污染物(n = 12)或不确定(n = 3)。与琼脂平板法培养相比,使用BACTEC Peds Plus/F瓶培养总体上检测到的病原体显著更多(62种病原体对51种病原体[P = 0.001]),总体上检测到的污染物显著更少(1种污染物对11种污染物[P = 0.006])。这些结果表明,在检测滑液标本中具有临床意义的微生物方面,BACTEC Peds Plus/F瓶比传统琼脂平板法具有更好的性能。