• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Continuous urea monitoring in hemodialysis: a model approach to forecast dialytic performance. Results of a multicenter study.

作者信息

Arrigo G, Tetta C, Santoro A, Ghezzi P, Ronco C, Colasanti G, La Greca G, Zucchelli P, D'Amico G

机构信息

Division of Nephrology, San Carlo Borromeo Hospital, Milan, Italy.

出版信息

J Nephrol. 2001 Nov-Dec;14(6):481-7.

PMID:11783604
Abstract

BACKGROUND

A urea biosensor, inserted into the ultrafiltrate collection-line of paired filtration dialysis (PFD), not only allows on-line dialysis quantification, but also forecasts final (Cend) and 30 min equilibrated urea concentration (Ceq), the most reliable value for calculating dialysis efficiency. The urea biosensor processes plasma ultrafiltrate continuously, delivering a large amount of data to the computer, which estimates the parameters by a mathematical model, thus predicting the whole urea profile with rebound.

METHODS

A multicenter randomized trial on 41 patients was conducted to ascertain the ability of a two-pool variable-volume urea model to forecast Cend and Ceq at 60 and 90 min after the start of dialysis. Two alternative dialytic treatments, A or B, were chosen, the latter being more efficient. Each treatment included six serial PFD. The accuracy of forecasting was evaluated through four indices based on forecast errors, calculated as the difference between observed and forecasted urea values: mean percent error (MPE) (%), mean absolute deviation (MAD) (mg/dl), mean absolute percent error (MAPE) (%) and root mean squared error (RMSE) (mg/dl).

RESULTS

Forecasted urea concentrations were lower than those measured by the biosensor. MPE for Cend was negligible in A (+1.2%) and much higher in B (+7.2%); both values improved at 90 min, +1.0% and +5.8%, respectively. MAD for Cend was similar in both treatments and improved slightly at 90 min, ranging from 4.9 to 5.9 mg/dl. MPE for Ceq was +4% in A and and more than doubled in B (+11.5%); both values improved at 90 min, +3.7% and +9.7%, respectively. MAD for Ceq was 7.5 mg/dl in A and 8.5 mg/dl in B; both improved at 90 min, 6.7 and 7.4 m g/dl, respectively. The other indices, MAPE and RMSE, showed similar results. Comparison between the errors of the two treatments with analysis of variance (ANOVA) for repeated measures gave no significant results.

CONCLUSIONS

Our model forecasts of urea concentrations were overall lower than the measured ones: the bias was negligible for A-Cend, greater for the A-Ceq and when the more efficient treatment B was used. The 60 min predictions improved at 90 min. The comparison between the prediction errors in the two treatments were not statistically significant. The recirculation measurement would probably reduce the bias if it were properly incorporated into the model.

摘要

相似文献

1
Continuous urea monitoring in hemodialysis: a model approach to forecast dialytic performance. Results of a multicenter study.
J Nephrol. 2001 Nov-Dec;14(6):481-7.
2
A new Bayesian method to forecast and fine tune individual hemodialysis dose.一种预测和微调个体血液透析剂量的新贝叶斯方法。
Hemodial Int. 2004 Jul 1;8(3):244-56. doi: 10.1111/j.1492-7535.2004.01102.x.
3
Haemodialysis with on-line monitoring equipment: tools or toys?配备在线监测设备的血液透析:是工具还是玩具?
Nephrol Dial Transplant. 2005 Jan;20(1):22-33. doi: 10.1093/ndt/gfh555.
4
Application of Individualized Bayesian Urea Kinetic Modeling to pediatric hemodialysis.个体化贝叶斯尿素动力学模型在儿科血液透析中的应用。
ASAIO J. 2010 May-Jun;56(3):246-53. doi: 10.1097/MAT.0b013e3181cf07d2.
5
On-line urea kinetics in haemodiafiltration.血液透析滤过中的在线尿素动力学
Nephrol Dial Transplant. 1996 Jun;11(6):1084-92.
6
Biochemical aspects and clinical perspectives of continuous urea monitoring in plasma ultrafiltrate. Preliminary results of a multicenter study.血浆超滤液中尿素连续监测的生化方面及临床前景。一项多中心研究的初步结果。
Int J Artif Organs. 1995 Sep;18(9):544-7.
7
Mathematical analysis of urea rebound in long-term hemodialysis patients.长期血液透析患者尿素反弹的数学分析
Ther Apher Dial. 2005 Apr;9(2):167-72. doi: 10.1111/j.1774-9987.2005.00231.x.
8
Direct determination of blood recirculation rate in hemodialysis by a conductivity method.通过电导率法直接测定血液透析中的血液再循环率。
ASAIO J. 1998 Jan-Feb;44(1):68-73.
9
[Urea distribution volume and ionic dialysance].[尿素分布容积与离子透析率]
G Ital Nefrol. 2004 Nov-Dec;21 Suppl 30:S226-30.
10
Dosing intermittent haemodialysis in the intensive care unit patient with acute renal failure--estimation of urea removal and evidence for the regional blood flow model.重症监护病房急性肾衰竭患者间歇性血液透析的剂量——尿素清除率估算及区域血流模型证据
Nephrol Dial Transplant. 2008 Jul;23(7):2286-98. doi: 10.1093/ndt/gfm938. Epub 2008 Feb 13.