Suppr超能文献

哈里斯-加兰特髋臼组件中的聚乙烯衬垫脱位:7例报告

Polyethylene liner dissociation in Harris-Galante acetabular components: a report of 7 cases.

作者信息

Werle Jason, Goodman Stuart, Schurman David, Lannin John

机构信息

Division of Orthopaedic Surgery, Stanford University Medical Center, Stanford, California 94305, USA.

出版信息

J Arthroplasty. 2002 Jan;17(1):78-81. doi: 10.1054/arth.2002.29327.

Abstract

Harris-Galante modular acetabular components (Zimmer, Warsaw, IN) have been used widely for primary and revision total hip arthroplasties. The survivorship of this implant has been well documented in the literature. Failure of the liner locking mechanism and subsequent dissociation of the polyethylene liner from the metal-backed shell is a potential cause of failure, however. We report 7 cases of liner dissociation and propose the mode of failure. The result in all cases was a well-fixed metal acetabular shell with a failed locking mechanism, which usually is managed by revision of the entire component. This procedure may be accompanied by the potential loss of acetabular bone stock, which should be replenished.

摘要

哈里斯-加兰特模块化髋臼组件(捷迈公司,华沙,印第安纳州)已广泛应用于初次和翻修全髋关节置换术。该植入物的生存率在文献中有充分记载。然而,衬垫锁定机制失效以及随后聚乙烯衬垫与金属背衬壳分离是潜在的失败原因。我们报告了7例衬垫分离病例并提出了失败模式。所有病例的结果都是金属髋臼壳固定良好但锁定机制失败,这种情况通常通过翻修整个组件来处理。此手术可能伴随着髋臼骨量的潜在损失,应予以补充。