Fukui Kiyokazu, Kaneuji Ayumi, Sugimori Tanzo, Ichiseki Toru, Matsumoto Tadami
Department of Orthopaedic Surgery, Kanazawa Medical University, 1-1 Daigaku, Uchinada-machi, Kahokugun, Ishikawa, 920-0293, Japan,
Eur J Orthop Surg Traumatol. 2014 Oct;24(7):1197-202. doi: 10.1007/s00590-013-1397-5. Epub 2013 Dec 31.
Zirconia femoral heads were introduced for total hip arthroplasty (THA) with the expectation of lower polyethylene (PE) wear and better clinical results. Because several studies reported poor survivorship of yttria-stabilized zirconia-PE THA, we investigated a new-generation yttria-stabilized zirconia head (diameter, 26 mm) manufactured by NGK Spark Plug. We retrieved six zirconia heads at revision THA after they had been in place for a mean of 8.6 years and measured their surface roughness and mean monoclinic content. Although their mean monoclinic content was higher than that of the unused head, surface roughness in the implanted heads was as low as that of the unused head, indicating that wear reduction may be possible with the selection of a suitable zirconia femoral head.
氧化锆股骨头被引入全髋关节置换术(THA),以期减少聚乙烯(PE)磨损并获得更好的临床效果。由于多项研究报告称钇稳定氧化锆-PE全髋关节置换术的生存率较低,我们对日本碍子株式会社制造的新一代钇稳定氧化锆股骨头(直径26毫米)进行了研究。我们在翻修全髋关节置换术中取出了六个氧化锆股骨头,这些股骨头平均在位8.6年,然后测量了它们的表面粗糙度和平均单斜晶含量。尽管它们的平均单斜晶含量高于未使用的股骨头,但植入股骨头的表面粗糙度与未使用的股骨头一样低,这表明选择合适的氧化锆股骨头可能会减少磨损。