Walker J, Colman G, Hughes M
J Immunol Methods. 1979;31(3-4):303-14. doi: 10.1016/0022-1759(79)90143-1.
A radioimmunoassay (RIA) has been developed to measure class-specific antibodies to Steptococcus mutans in the serum and saliva of monkeys (Macaca fascicularis). Anti-human immunoglobulin antibodies purified by affinity chromatography on immobilised monkey immunoglobulins and labelled with 125I were employed. Formolised cells of S. mutans and an extract of culture supernatant adsorbed to polystyrene wells were used as solid-phase antigens. The coefficients of variation for IgG, IgA and IgM assays were less than or equal to 10% for both antigen systems. Two monkeys were immunised with formolised cells of S. mutans by subcutaneous injection and subsequent instillation of bacterial cells into their right parotid ducts. IgG, IgA and IgM antibody responses to S. mutans in samples of serum and saliva were quantitated by RIA. Immobilisation of purified components of S. mutans on polystyrene wells enabled the measurement of antibody response to a number of antigens to be made. The RIA is a sensitive, reproducible and quantitative method of measuring serum and salivary antibody responses in monkeys.
已开发出一种放射免疫分析法(RIA),用于测量猕猴(食蟹猴)血清和唾液中针对变形链球菌的类特异性抗体。使用通过固定化猴免疫球蛋白进行亲和层析纯化并标记有125I的抗人免疫球蛋白抗体。变形链球菌的甲醛化细胞和吸附到聚苯乙烯孔上的培养上清液提取物用作固相抗原。两种抗原系统的IgG、IgA和IgM检测的变异系数均小于或等于10%。通过皮下注射并用随后将细菌细胞滴入其右腮腺导管的方式,用变形链球菌的甲醛化细胞对两只猴子进行免疫。通过RIA对血清和唾液样本中针对变形链球菌的IgG、IgA和IgM抗体反应进行定量。将变形链球菌的纯化成分固定在聚苯乙烯孔上,能够测量对多种抗原的抗体反应。RIA是一种测量猴子血清和唾液抗体反应的灵敏、可重复且定量的方法。