Suppr超能文献

绝经后出血患者三维超声子宫内膜容积测量的可重复性

Reproducibility of three-dimensional ultrasound endometrial volume measurements in patients with postmenopausal bleeding.

作者信息

Yaman C, Ebner T, Jesacher K, Obermayr G, Pölz W, Tews G

机构信息

Women's General Hospital, Department of Assisted Reproduction, Linz, Austria.

出版信息

Ultrasound Obstet Gynecol. 2002 Mar;19(3):282-6. doi: 10.1046/j.1469-0705.2002.00644.x.

Abstract

OBJECTIVE

To evaluate the reproducibility of transvaginal three-dimensional (3D) endometrial volume measurement in patients with postmenopausal bleeding and to compare the reproducibility of this technique to that of two-dimensional (2D) endometrial thickness measurement.

METHODS

In a prospective, blinded study, transvaginal ultrasound examinations were performed in 51 consecutive patients with postmenopausal bleeding. Three-dimensional volume and 2D thickness measurements were made and intraobserver and interobserver reproducibility of each technique were assessed.

RESULTS

The intraobserver correlation of 3D endometrial volume measurement of the first observer was 0.97 and that of the second observer was 0.99. Thus, mean intraobserver correlation was 0.98. The mean interobserver correlation was 0.95 (0.95 vs. 0.96). There was no significant difference in reproducibility at different volume cut-offs. The mean intra- and interobserver correlation of endometrium volume measurements for five patients with endometrial carcinoma did not differ significantly from that for patients without carcinoma (0.98, 0.98 vs. 0.98, 0.95). The intraobserver correlation of 2D endometrial thickness measurements from the first observer was 0.71 and that from second observer 0.87. Thus, mean intraobserver correlation of the endometrial thickness measurements was 0.79. The mean interobserver correlation was 0.76 (0.84 vs. 0.70).

CONCLUSIONS

Endometrial volume and thickness measurements by 3D and 2D ultrasound, respectively, show good reproducibility but the reproducibility of 3D ultrasound is better.

摘要

目的

评估经阴道三维(3D)子宫内膜容积测量在绝经后出血患者中的可重复性,并将该技术的可重复性与二维(2D)子宫内膜厚度测量的可重复性进行比较。

方法

在一项前瞻性、盲法研究中,对51例连续的绝经后出血患者进行经阴道超声检查。进行三维容积和二维厚度测量,并评估每种技术的观察者内和观察者间的可重复性。

结果

第一位观察者的3D子宫内膜容积测量的观察者内相关性为0.97,第二位观察者为0.99。因此,观察者内平均相关性为0.98。观察者间平均相关性为0.95(0.95对0.96)。在不同的容积临界值下,可重复性无显著差异。5例子宫内膜癌患者的子宫内膜容积测量的观察者内和观察者间平均相关性与非癌患者相比无显著差异(0.98,0.98对0.98,0.95)。第一位观察者的2D子宫内膜厚度测量的观察者内相关性为0.71,第二位观察者为0.87。因此,子宫内膜厚度测量的观察者内平均相关性为0.79。观察者间平均相关性为0.76(0.84对0.70)。

结论

分别通过3D和2D超声测量子宫内膜容积和厚度均显示出良好的可重复性,但3D超声的可重复性更好。