Bukovic J A, Johnson H M
Appl Microbiol. 1975 Oct;30(4):700-1. doi: 10.1128/am.30.4.700-701.1975.
A solid-phase radioimmunoassay test employing 125I-labeled enterotoxin C and polystyrene tubes coated with specific antibody was used for the detection and quantitation of entertoxin C in condensed milk, cheddar cheese, custard, and ham salad. The assay was sensitive to 1 to 10 ng of toxin per g of food; nonspecific inhibitions were 16% or less.
采用125I标记的肠毒素C和包被有特异性抗体的聚苯乙烯管进行的固相放射免疫测定试验,用于检测和定量炼乳、切达干酪、蛋奶沙司和火腿沙拉中的肠毒素C。该测定对每克食物中1至10纳克的毒素敏感;非特异性抑制率为16%或更低。