Seely John F, Uspenskii Yu A, Pershin Yu P, Kondratenko V V, Vinogradov A V
Naval Research Laboratory, Space Science Division, Washington DC 20375, USA.
Appl Opt. 2002 Apr 1;41(10):1846-51. doi: 10.1364/ao.41.001846.
A Sc-Si multilayer coating was applied to a replica of the 3600 groove/mm grating, developed for the SO82A spectroheliograph that flew on the Skylab mission, for the purpose of enhancing the normal-incidence efficiency in the extreme-ultraviolet region. The efficiency, measured at an angle of incidence of 6 degrees with synchrotron radiation, had a maximum value of 7.2% at a wavelength of 38 nm and was a factor of 3 higher than the efficiency of the gold-coated Skylab grating. The measured efficiency of the Sc-Si grating was in good agreement with the efficiency calculated by use of the modified integral method.