Kang H K, Beaumont P E, Taylor H R, van Saarloos P P, Constable I J
University of Sydney, Sydney, Australia.
Aust N Z J Ophthalmol. 1995 Nov;23(4):265-72. doi: 10.1111/j.1442-9071.1995.tb00175.x.
To compare the performance of the three excimer laser delivery systems in correcting myopia.
The first generation excimer laser systems produced by Summit, VISX and LEI were examined. The first 40 consecutive eyes with six-month refractive results were selected from the LEI centre. Forty consecutive eyes, matched for age and attempted corrections, were then selected from each of the Summit and VISX centres. The postoperative visual results were examined retrospectively and compared among the three groups.
At six-month follow-up, the mean and standard deviation of the spherical equivalent refraction were +0.27 (SD, 0.65) dioptre in the Summit group, -0.33 (SD, 0.83) dioptre in the VISX group and -0.62 (SD, 0.89) dioptre in the LEI group (P = 0.0001, ANOVA). Thirty-five eyes (88%) in the Summit group, 33 eyes (83%) in the VISX group and 28 eyes (70%) in the LEI group achieved corrections within 1 dioptre of intended corrections (P = 0.131, chi 2 test). Four eyes (10%) in the Summit group, two eyes (5%) in the VISX group and one eye (3%) in the LEI group were overcorrected by more than 1 dioptre at six-month follow-up. Unaided visual acuity (Snellen equivalent) was 6/12 or better in 37 eyes (93%) in the Summit group, 34 eyes (85%) in the VISX group and 34 eyes (87%) in the LEI group (data missing in one eye). Loss of one or more lines of best corrected visual acuity (Snellen equivalent) was found in 6 of 39 eyes (15%) in the Summit group, 10 of 40 eyes (25%) in the VISX group and 4 of 36 eyes (11%) in the LEI group (P = 0.258, chi 2 test). Regression between one and six month follow-up differed significantly (P = 0.001, ANOVA) among the groups, with the mean of -1.25 (SD, 0.94) dioptres in the Summit group, -0.59 (SD, 1.01) dioptre in the VISX group and -0.40 (SD, 0.99) dioptre in the LEI group.
Statistically comparable results were found in the three groups in terms of refraction and visual acuity six months after myopic photorefractive keratectomy. No statistical differences were found between the groups in terms of significant overcorrection or loss of best corrected acuity. The group treated using the Summit system demonstrated significantly greater regression than the other groups, necessitating larger initial hyperopic shifts.
比较三种准分子激光传输系统矫正近视的性能。
对Summit、VISX和LEI生产的第一代准分子激光系统进行检测。从LEI中心选取连续40只眼,这些眼有6个月的屈光结果。然后从Summit和VISX中心分别选取40只年龄和预期矫正度数匹配的连续眼。对术后视力结果进行回顾性检查并在三组之间进行比较。
在6个月随访时,Summit组等效球镜度的均值和标准差为+0.27(标准差,0.65)屈光度,VISX组为-0.33(标准差,0.83)屈光度,LEI组为-0.62(标准差,0.89)屈光度(P = 0.0001,方差分析)。Summit组35只眼(88%)、VISX组33只眼(83%)和LEI组28只眼(70%)的矫正度数在预期矫正度数的1屈光度范围内(P = 0.131,卡方检验)。在6个月随访时,Summit组4只眼(10%)、VISX组2只眼(5%)和LEI组1只眼(3%)的矫正度数超过预期矫正度数1屈光度以上。Summit组37只眼(93%)、VISX组34只眼(85%)和LEI组34只眼(87%)(1只眼数据缺失)的裸眼视力(Snellen等效值)为6/12或更好。Summit组39只眼中6只眼(15%)、VISX组40只眼中10只眼(25%)和LEI组36只眼中4只眼(11%)出现最佳矫正视力(Snellen等效值)下降一行或多行(P = 0.258,卡方检验)。三组在1个月和6个月随访之间的屈光度回退有显著差异(P = 0.001,方差分析),Summit组均值为-1.25(标准差,0.94)屈光度,VISX组为-0.59(标准差,1.01)屈光度,LEI组为-0.40(标准差,0.99)屈光度。
近视性光性屈光性角膜切削术后6个月,三组在屈光和视力方面的结果在统计学上具有可比性。在显著过矫或最佳矫正视力丧失方面,各组之间未发现统计学差异。使用Summit系统治疗的组显示出比其他组显著更大的屈光度回退,因此需要更大的初始远视偏移。