Sparreboom Alex, Zhao Ming, Brahmer Julie R, Verweij Jaap, Baker Sharyn D
Laboratory of Experimental Chemotherapy and Pharmacology, Department of Medical Oncology, Rotterdam Cancer Institute (Daniel den Hoed Kliniek) and University Hospital Rotterdam, Groene Hilledijk 301, The Netherlands.
J Chromatogr B Analyt Technol Biomed Life Sci. 2002 Jun 25;773(2):183-90. doi: 10.1016/s1570-0232(02)00167-8.
A new simple method was developed for the quantitative determination of the docetaxel (Taxotere) vehicle, polysorbate 80 (Tween 80), in human plasma. Calibration curves were constructed in the range of 1-100 microg/ml, using paclitaxel (0.01 mM) as internal standard, and were analyzed using a power fit with equal weighting. Sample pretreatment involved a one-step extraction with acetonitrile-n-butyl chloride (1:4, v/v). The analytes were separated on a Waters X-Terra MS column (50x2.1 mm I.D.) packed with 3.5-microm ODS material, and eluted with methanol-water (9:1, v/v) containing 0.1% formic acid. The column effluent was monitored by tandem mass spectrometry with electrospray ionization. The overall extraction efficiency was 50-60%, with values for precision and accuracy of < or =16% and <15% relative error, respectively. Our current method is approximately 60-100-fold more sensitive than previous assays, and will be used to define Tween 80 disposition in patients receiving Taxotere.
开发了一种新的简单方法用于定量测定人血浆中多西他赛(泰索帝)的溶媒聚山梨酯80(吐温80)。以紫杉醇(0.01 mM)为内标,在1 - 100 μg/ml范围内构建校准曲线,并采用等权重幂拟合进行分析。样品预处理包括用乙腈 - 正丁基氯(1:4,v/v)一步萃取。分析物在填充有3.5-μm ODS材料的沃特世X-Terra MS柱(内径50x2.1 mm)上分离,并用含0.1%甲酸的甲醇 - 水(9:1,v/v)洗脱。柱流出物通过电喷雾电离串联质谱进行监测。总体萃取效率为50 - 60%,精密度值≤16%,相对误差<15%。我们目前的方法比以前的测定方法灵敏度高约60 - 100倍,将用于确定接受泰索帝治疗患者体内吐温80的处置情况。