Kuroda Teruhito, Fujikado Takashi, Maeda Naoyuki, Oshika Tetsuro, Hirohara Youko, Mihashi Toshifumi
Department of Applied Medical Engineering, Osaka University Medical School, Japan.
Am J Ophthalmol. 2002 Jul;134(1):1-9. doi: 10.1016/s0002-9394(02)01402-2.
To compare the higher-order aberrations of the oculus (whole eye) and cornea in eyes with mild cortical or nuclear cataract and to estimate the effect of ocular higher-order aberrations on the loss of contrast sensitivity using wavefront analysis.
Observational case series.
Six eyes of four patients with mild nuclear cataract, 18 eyes of 14 patients with mild cortical cataract, and nine eyes of nine normal patients were examined. Wavefront aberrations of the oculus and cornea for central 6 mm diameter were measured using the Hartmann-Shack (HS) aberrometer. Higher-order aberrations were calculated with Zernike polynomials up to sixth order. The relationship between average lens density (ALD) measured by the Scheimpflug camera and the ocular total higher-order aberration (OTHA) was investigated. The relationship between contrast sensitivity (CS) and the OTHA or ALD was also examined.
The OTHA was significantly larger in cataracts compared with normal subjects, while corneal total higher-order aberration did not differ between cataracts and normal subjects. The polarity of spherical aberration was negative in all eyes with nuclear cataract while positive in all eyes with cortical cataract. The correlation between ALD and OTHA was not significant in eyes with cataracts. The CS highly correlated with OTHA while it moderately correlated with ALD.
The HS aberrometer is useful to objectively evaluate the deterioration of images in eyes with mild cataract and it revealed that the polarity of spherical aberration was different between nuclear and cortical cataract. It was also suggested that in mild nuclear or cortical cataract, not only light scattering, but also optical aberration of the lens contributes to the loss of contrast sensitivity.
比较轻度皮质性或核性白内障患者患眼(全眼)和角膜的高阶像差,并使用波前分析评估眼高阶像差对对比敏感度降低的影响。
观察性病例系列。
检查了4例轻度核性白内障患者的6只眼、14例轻度皮质性白内障患者的18只眼和9例正常患者的9只眼。使用哈特曼-夏克(HS)像差仪测量直径6mm中心区域的患眼光学像差和角膜像差。用泽尼克多项式计算直至六阶的高阶像差。研究了通过Scheimpflug相机测量的平均晶状体密度(ALD)与眼总高阶像差(OTHA)之间的关系。还检查了对比敏感度(CS)与OTHA或ALD之间的关系。
与正常受试者相比,白内障患者的OTHA显著更大,而白内障患者与正常受试者的角膜总高阶像差无差异。所有核性白内障患眼的球差极性为负,而所有皮质性白内障患眼的球差极性为正。白内障患眼中ALD与OTHA之间的相关性不显著。CS与OTHA高度相关,而与ALD中度相关。