文献检索文档翻译深度研究
Suppr Zotero 插件Zotero 插件
邀请有礼套餐&价格历史记录

新学期,新优惠

限时优惠:9月1日-9月22日

30天高级会员仅需29元

1天体验卡首发特惠仅需5.99元

了解详情
不再提醒
插件&应用
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
高级版
套餐订阅购买积分包
AI 工具
文献检索文档翻译深度研究
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2025

类风湿关节炎中的库多肘关节假体:对24例患者的26次肘关节置换进行连续系列研究,前瞻性随访平均5年。

The Kudo elbow prosthesis in rheumatoid arthritis: a consecutive series of 26 elbow replacements in 24 patients followed prospectively for a mean of 5 years.

作者信息

Rahme Hans

机构信息

Department of Orthopaedics, Uppsala University Hospital, Sweden.

出版信息

Acta Orthop Scand. 2002 Jun;73(3):251-6. doi: 10.1080/000164702320155202.


DOI:10.1080/000164702320155202
PMID:12143968
Abstract

The Kudo prosthesis is the most commonly used elbow implant in Sweden. However, there are few reports of the results, besides those reported by Kudo himself. I have implanted 30 Kudo type 4 or 5 elbow prostheses in 28 patients with rheumatoid arthritis. 3 arthroplastics were revised, 2 because of loosening and 1 because of a periprosthetic ulnar fracture. 6 major peroperative or early postoperative complications occurred, but only 1 of these was a failure. 2 patients developed postoperative ulnar neuropathy, one was transient and the other patient died 1 year after surgery. 26 elbows were available for follow-up at an average 5 (2-8) years after implantation. All 26 functioned well although radiographic loosening of the humeral component was found in 1 patient. The average range of flexion increased by 14 degrees while the extension lag was unchanged (35 degrees). Activities of daily living had improved markedly and all but 3 patients were satisfied with their elbow. Radiolucent lines were seen around the proximal part of the ulnar component in 18/26 elbows. Although progressive in 1 patient only, this is a matter of concern, indicating that this component may be the weak part of the Kudo prosthesis.

摘要

库多假体是瑞典最常用的肘部植入物。然而,除了库多本人报告的结果外,关于其结果的报道很少。我已为28例类风湿性关节炎患者植入了30个库多4型或5型肘部假体。3例关节成形术进行了翻修,2例因松动,1例因假体周围尺骨骨折。发生了6例主要的术中或术后早期并发症,但其中只有1例失败。2例患者出现术后尺神经病变,1例为短暂性,另1例患者在术后1年死亡。26个肘部在植入后平均5(2 - 8)年可进行随访。尽管在1例患者中发现肱骨部件有影像学松动,但所有26个肘部功能良好。平均屈曲范围增加了14度,而伸展滞后未改变(35度)。日常生活活动有明显改善,除3例患者外,所有患者对其肘部情况满意。在26个肘部中的18个肘部,尺骨部件近端周围可见射线可透性线。虽然仅在1例患者中呈进行性,但这是一个值得关注的问题,表明该部件可能是库多假体的薄弱部分。

相似文献

[1]
The Kudo elbow prosthesis in rheumatoid arthritis: a consecutive series of 26 elbow replacements in 24 patients followed prospectively for a mean of 5 years.

Acta Orthop Scand. 2002-6

[2]
Stable fixation of the ulnar component in the Kudo elbow prosthesis. A radiostereometric (RSA) study of 13 prostheses with 2-year follow-up.

Acta Orthop. 2005-2

[3]
[Kudo non-constrained elbow prosthesis for inflammatory and hemophilic joint disease: analysis in 30 cases].

Rev Chir Orthop Reparatrice Appar Mot. 2002-6

[4]
[The signification of total elbow replacement in the treatment of rheumatoid arthritis].

Ryumachi. 1993-4

[5]
Survivorship of the KUDO total elbow prosthesis--comparative study of cemented and uncemented ulnar components: 89 cases followed for an average of 6 years.

Acta Orthop. 2007-4

[6]
Micromotion of the Souter-Strathclyde total elbow prosthesis in patients with rheumatoid arthritis 21 elbows followed for 2 years.

Acta Orthop Scand. 2002-6

[7]
Kudo type-5 total elbow arthroplasty for patients with rheumatoid arthritis: a minimum ten-year follow-up study.

Bone Joint J. 2017-6

[8]
Souter-Strathclyde total elbow arthroplasty: medium-term results.

Acta Orthop Belg. 2003-12

[9]
Failure mechanisms in uncemented Kudo type 5 elbow prosthesis in patients with rheumatoid arthritis: 7 of 49 ulnar components revised because of loosening after 2-10 years.

Acta Orthop. 2007-4

[10]
Results with Kudo elbow prostheses in non-traumatic indications : a study of 36 cases.

Acta Orthop Belg. 2005-6

引用本文的文献

[1]
The age specific performance of elbow hemiarthroplasty: A systematic review.

Shoulder Elbow. 2025-7

[2]
Long-term results of the iBP elbow prosthesis: beware of destructive metallosis!

BMC Musculoskelet Disord. 2019-9-6

[3]
Systematic review of primary total elbow prostheses used for the rheumatoid elbow.

Clin Rheumatol. 2004-8

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

推荐工具

医学文档翻译智能文献检索