A method is described for particle sizing of pressurized metered suspension aerosols by collection in a settling drum followed by microscopic evaluation of the slides with a Quantimet 720 automatic image analyser. The method gives satisfactory representation of the distribution of particles settling to the drum base, and demonstrates the excellent stability and reproducibility between and within aerosol packs for two widely used inhalation products. There is much drug deposition of somewhat finer size distribution on the wall of the drum than on the drum base. In spite of this wall loss, the method gives only slightly higher results for the weight and number mean diameters, than when both wall and base distributions are considered. The Quantimet was found to be suitable for particle sizing salbutamol used in preparing aerosol products.

摘要

描述了一种通过在沉降鼓中收集,然后用Quantimet 720自动图像分析仪对载玻片进行显微镜评估来测定加压定量悬浮气雾剂颗粒大小的方法。该方法能令人满意地呈现沉降到鼓底部的颗粒分布情况,并证明了两种广泛使用的吸入产品在气雾剂包装之间和内部具有出色的稳定性和重现性。与鼓底部相比,鼓壁上有更多粒径分布稍细的药物沉积。尽管存在这种壁面损失,但与同时考虑壁面和底部分布时相比,该方法得出的重量平均直径和数量平均直径结果仅略高。已发现Quantimet适用于测定用于制备气雾剂产品的沙丁胺醇的颗粒大小。