AOAC Official Method 996.10, Assurance Enzyme Immunoassay (EIA) for Escherichia coli O157:H7 (EHEC), was modified to incorporate a new enrichment protocol using BioControl EHEC8 medium for testing raw and cooked beef. Foods were tested by EIA and the U.S. Department of Agriculture/Food Safety and Inspection Service (USDA/FSIS) enrichment conditions and the FDA Bacteriological Analytical Manual (BAM) isolation and confirmation techniques. A total of 14 collaborators participated. Raw and cooked ground beef were inoculated with E. coli O157:H7 at 2 different levels: a high level where predominantly positive results were expected, and a low level where fractional recovery was anticipated. Collaborators tested 378 test portions and controls by both the 8 h EIA and the USDA/FSIS enrichment methods, for a total of 756 test portions. Of the 378 paired test portions, 75 were positive and 212 were negative by both methods. Thirteen test portions were presumptively positive by EIA and could not be confirmed culturally; 30 were negative by EIA, but confirmed positive by culture; and 65 were negative by the culture method, but confirmed positive by the EIA method. There was no statistical difference between results obtained with the Assurance EIA for EHEC 8 h method and the culture method for raw ground beef. The Assurance EIA had a significantly higher recovery for cooked beef.

摘要

美国公职分析化学家协会(AOAC)官方方法996.10,即大肠杆菌O157:H7(肠出血性大肠杆菌)的保证酶免疫测定法(EIA),进行了修改,纳入了一种使用BioControl EHEC8培养基的新富集方案,用于检测生牛肉和熟牛肉。食品通过EIA以及美国农业部/食品安全与检验局(USDA/FSIS)的富集条件和美国食品药品监督管理局(FDA)《细菌学分析手册》(BAM)的分离与确证技术进行检测。共有14名合作者参与。将生牛肉末和熟牛肉末用两种不同水平的大肠杆菌O157:H7接种:一个高水平,预期主要得到阳性结果;一个低水平,预期回收率较低。合作者通过8小时EIA和USDA/FSIS富集方法对378个测试部分和对照进行了检测,总共756个测试部分。在378对测试部分中,两种方法均为阳性的有75个,均为阴性的有212个。13个测试部分通过EIA初步判定为阳性,但无法通过培养确证;30个通过EIA为阴性,但培养确证为阳性;65个通过培养方法为阴性,但通过EIA方法确证为阳性。对于生牛肉末,EHEC 8小时保证EIA方法和培养方法所得结果之间无统计学差异。对于熟牛肉,保证EIA的回收率显著更高。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验