Suppr超能文献

[使用海德堡视网膜断层扫描仪(HRT)对视神经乳头玻璃膜疣进行定量和客观的地形图分析]

[Quantitative and objective topometrical analysis of drusen of the optic nerve head with the Heidelberg retina tomograph (HRT)].

作者信息

Kuchenbecker J, Wecke T, Vorwerk C K, Behrens-Baumann W

机构信息

Augenklinik der Otto-von-Guericke Universität Magdeburg, Germany.

出版信息

Ophthalmologe. 2002 Oct;99(10):768-73. doi: 10.1007/s00347-002-0639-4.

Abstract

BACKGROUND AND PURPOSE

Optic nerve head drusen (ONHD) are one of the most frequent causes for congenital swelling of the optic nerve head. Visual field and retinal nerve fiber layer defects are reported in cases of ONHD. The Heidelberg Retina Tomograph (HRT) allows a 3-dimensional topometric analysis of the optic nerve disc and measurement of the peripapillary mean retinal nerve fiber layer.

PATIENTS AND METHODS

A total of 18 eyes from 9 patients with sonographically confirmed drusen were analyzed with the HRT. Data were compared to a control group of 18 eyes from 9 matched healthy individuals. Statistical analyses were performed by using ANOVA (univariate). All patients with ONHD underwent a computerised visual field test (30 degrees, Octopus 101). Due to a bad reliability factor of over 10 in the visual fields by 4 out of 18 eyes, only measurements from 14 eyes were included in the study. We correlated visual field and HRT parameters and calculated the Pearson's correlation coefficient (r).

RESULTS

We found a significant difference in the measured parameter mean retinal nerve fiber layer (RNFL) thickness ( p<0.05) between the two groups. In the ONHD group a negative correlation coefficient was found between the peripapillary mean RNFL thickness and the loss variance (r=-0.50, p=0.03) as well as between the peripapillary RNFL cross-sectional area and the loss variance (r=-0.47, p=0.04).

CONCLUSIONS

The HRT is able to detect a peripapillary RNFL thinning in cases with ONHD. The mean RNFL thickness correlated with the loss variance. The HRT should be used to perform a quantitative and objective topometric analysis in cases with ONHD.

摘要

背景与目的

视乳头玻璃膜疣(ONHD)是导致视乳头先天性肿胀的最常见原因之一。据报道,ONHD患者存在视野和视网膜神经纤维层缺损。海德堡视网膜断层扫描仪(HRT)可对视神经盘进行三维地形图分析,并测量视乳头周围平均视网膜神经纤维层厚度。

患者与方法

对9例经超声检查确诊为玻璃膜疣的患者的18只眼进行HRT分析。将数据与9名匹配的健康个体的18只眼组成的对照组进行比较。采用方差分析(单因素)进行统计分析。所有ONHD患者均接受了计算机视野检查(30度,Octopus 101)。由于18只眼中有4只眼的视野可靠性因子超过10,因此本研究仅纳入了14只眼的测量数据。我们对视野和HRT参数进行了相关性分析,并计算了Pearson相关系数(r)。

结果

我们发现两组之间测量参数平均视网膜神经纤维层(RNFL)厚度存在显著差异(p<0.05)。在ONHD组中,视乳头周围平均RNFL厚度与缺损方差之间存在负相关系数(r=-0.50,p=0.03),视乳头周围RNFL横截面积与缺损方差之间也存在负相关系数(r=-0.47,p=0.04)。

结论

HRT能够检测出ONHD患者视乳头周围RNFL变薄。平均RNFL厚度与缺损方差相关。在ONHD患者中,应使用HRT进行定量和客观的地形图分析。