Suppr超能文献

Quality of therapeutic plasma-requirements for marketing authorization.

作者信息

Heiden Margarethe, Seitz Rainer

机构信息

Paul-Ehrlich-Institut, D-63225, Langen, Germany.

出版信息

Thromb Res. 2002 Oct 31;107 Suppl 1:S47-51. doi: 10.1016/s0049-3848(02)00152-4.

Abstract

Fresh frozen plasma (FFP) contains higher levels of intact coagulation factors and coagulation and fibrinolysis inhibitors than solvent/detergent-treated plasma (SD plasma), and also greater residual cell contamination. SD plasma is a particle-free plasma of uniform quality. SD treatment, however, has the specific result of reducing the activities of some inhibitors. Both plasma types carry a minimal residual risk of transmitting human immunodeficiency virus (HIV)-1/2, hepatitis virus B (HBV), and hepatitis virus C (HCV), but SDP is, in addition, also safe with respect to other lipid-enveloped viruses and perhaps with respect to hepatitis virus A (HAV), also due to its antibody (Ab) content. Future revisions of therapeutic plasma safety and quality standards should consider the following points:For FFP:reduce residual cell count in all FFP units to values below 5 x 10(6) leukocytes/l;screen donors for Parvovirus B19 genome and antibodies in order to establish a sufficiently large collection of genome-negative and antibody-positive donors whose FFP can be used for selected patients;For SDP:introduce pool testing for Parvovirus B19 genome; fix an upper limit for genome and a lower limit for antibody content;in addition to the standard quality control methods for therapeutic plasma, focus on assays to test for functionally intact proteinase inhibitors such as alpha(2)antiplasmin (alpha(2)AP) and alpha(1)proteinase inhibitor (alpha(1)PI) that are important for plasma indications. Commercially available kits may not be sufficient to show changes in inhibition kinetics. For both types:introduce an activation marker such as thrombin-antithrombin complex (TAT) as a random test to monitor activation processes during withdrawal, separation, manufacturing, and storage;abolish inappropriate parameters like Antithrombin III (AT III) and coagulation factor XI that are not relevant for changes in plasma quality;finally, support every effort towards establishing an efficient documentation and reporting system on efficacy and side effects of plasma transfusions. Effective reporting alone might help to reveal deficiencies of specific plasma quality and to overcome them through modifications to manufacturing processes and testing, or by defining its indications more precisely.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验