Rogachefsky Arlene S, Becker Kenneth, Weiss Glen, Goldberg David J
Skin Laser & Surgery Specialists of New York and New Jersey, Hackensack, NJ, USA.
Dermatol Surg. 2002 Oct;28(10):932-5; discussion 936. doi: 10.1046/j.1524-4725.2002.02070.x.
Effective hair removal continues to pose a challenge to the physician. The use of lasers represents a significant advance in epilation, but still requires further refinement. The long-pulsed Nd:YAG laser may offer advantages over other systems because of its significant depth of penetration and minimal absorption by epidermal melanin, but ideal parameters need to be determined.
To evaluate the efficacy of a long-pulsed Nd:YAG laser system and determine the optimal parameters for hair removal.
Twenty-two subjects were treated with a cryogen spray-cooled long-pulsed Nd:YAG laser. Four adjacent sites were assigned to each subject, where the following sets of parameters were utilized: 50 J/cm2 with a 25-msec pulse duration, 60 J/cm2 with a 50-msec pulse duration, 80 J/cm2 with a 50-msec pulse duration, and control. Hair counts were obtained immediately, 1 week, 1 month, and 3 months after treatment, and multivariate regression analysis was used to determine the significance of hair reduction. Acute reactions and adverse events were also evaluated.
Treatment at all three sets of parameters resulted in significant mean hair reductions immediately, at 1 week, and at 1 month (P <.001). At 3 months, the higher settings of 60 J/cm2 and 50 msec and 80 J/cm2 and 50 msec were statistically significant for reduced mean hair counts (P =.014, P =.042, respectively), while the lowest setting at 50 J/cm2 and 25 msec was not significant (P =.079). Patient and physician assessments suggested optimal hair reduction at the highest fluence (80 J/cm2) and longest pulse duration (50 msec). The most common acute reactions were pain during treatment, erythema, and perifollicular edema, all of which were more severe with higher fluences.
The long-pulsed Nd:YAG laser is a safe and effective method of hair removal. Increased fluence (60-80 J/cm2) and longer pulse duration (50 msec) settings were generally correlated with reduced hair counts and improved clinical outcome.
有效的脱毛对医生来说仍然是一项挑战。激光的使用代表了脱毛技术的重大进步,但仍需要进一步完善。长脉冲Nd:YAG激光可能比其他系统具有优势,因为它具有显著的穿透深度且表皮黑色素吸收最少,但理想参数仍需确定。
评估长脉冲Nd:YAG激光系统的疗效并确定脱毛的最佳参数。
22名受试者接受了冷冻喷雾冷却的长脉冲Nd:YAG激光治疗。为每位受试者分配四个相邻部位,采用以下几组参数:能量密度50 J/cm²、脉冲持续时间25毫秒;能量密度60 J/cm²、脉冲持续时间50毫秒;能量密度80 J/cm²、脉冲持续时间50毫秒,以及对照组。在治疗后即刻、1周、1个月和3个月进行毛发计数,并采用多元回归分析确定毛发减少的显著性。还评估了急性反应和不良事件。
所有三组参数的治疗在治疗后即刻、1周和1个月时均导致显著的平均毛发减少(P <.001)。在3个月时,能量密度60 J/cm²和50毫秒以及80 J/cm²和50毫秒的较高设置在平均毛发计数减少方面具有统计学意义(分别为P =.014,P =.042),而能量密度50 J/cm²和25毫秒的最低设置不显著(P =.079)。患者和医生的评估表明,在最高能量密度(80 J/cm²)和最长脉冲持续时间(50毫秒)时脱毛效果最佳。最常见的急性反应是治疗期间的疼痛、红斑和毛囊周围水肿,所有这些在能量密度较高时都更严重。
长脉冲Nd:YAG激光是一种安全有效的脱毛方法。增加能量密度(60 - 80 J/cm²)和延长脉冲持续时间(50毫秒)的设置通常与毛发计数减少和临床效果改善相关。