Pellegrini Nicoletta, Del Rio Daniele, Colombi Barbara, Bianchi Marta, Brighenti Furio
Department of Public Health, University of Parma, Via Volturno, 39, Italy.
J Agric Food Chem. 2003 Jan 1;51(1):260-4. doi: 10.1021/jf020657z.
The 2,2'-azinobis(3-ethylbenzothiazoline-6-sulfonic acid) radical cation (ABTS()(+)) assay was adapted to a flow injection (FI) system to obtain a sensitive and rapid technique for the monitoring of antioxidant activity of pure compounds and complex matrixes, such as beverages and food extracts. The FI system includes a HPLC pump that flows the mobile phase (a solution of ABTS()(+) in ethanol) through a 20 microL loop injector, a single bead string reactor filled with acid-washed silanized beads, a delay coil and a photodiode array UV-visible detector. The technique was very sensitive, with limits of detection and of quantification of 4.14 and 9.29 micromol of Trolox/L, respectively, and demonstrated high repeatability and reproducibility. The proposed technique was then applied to the evaluation of the antioxidant activity of some pure compounds, demonstrating good agreement with published data obtained by the original spectrophotometric ABTS()(+) assay. Finally, the total antioxidant activity of 10 beverages was determined by both the proposed and the original method. The values ranged from 0.09 mmol L(-)(1) for cola to 49.24 mmol L(-)(1) for espresso coffee and did not result significantly different from those obtained by the original spectrophotometric ABTS()(+) assay (Student's paired t-test: t = 1.4074, p = 0.1929). In conclusion, the proposed FI technique seems suitable for the direct, rapid and reliable monitoring of total antioxidant activity of pure compounds and beverages and, due to the ability to operate in continuous, it allows the analysis of about 30 samples h(-)(1) making the assay particularly suitable for large screening of total antioxidant activity in food samples.
将2,2'-联氮-双-(3-乙基苯并噻唑啉-6-磺酸)自由基阳离子(ABTS()(+))分析法应用于流动注射(FI)系统,以获得一种灵敏且快速的技术,用于监测纯化合物以及诸如饮料和食品提取物等复杂基质的抗氧化活性。该FI系统包括一个使流动相(ABTS()(+)的乙醇溶液)流经20微升定量环进样器的高效液相色谱泵、一个填充有酸洗硅烷化珠子的单珠串反应器、一个延迟线圈和一个光电二极管阵列紫外可见检测器。该技术非常灵敏,检测限和定量限分别为4.14和9.29微摩尔Trolox/升,并且具有高重复性和再现性。然后将所提出的技术应用于评估一些纯化合物的抗氧化活性,结果表明与通过原始分光光度法ABTS()(+)分析获得的已发表数据具有良好的一致性。最后,用所提出的方法和原始方法测定了10种饮料的总抗氧化活性。其值范围从可乐的0.09毫摩尔L(-)(1)到浓缩咖啡的49.24毫摩尔L(-)(1),并且与通过原始分光光度法ABTS()(+)分析获得的值没有显著差异(学生配对t检验:t = 1.4074,p = 0.1929)。总之,所提出的FI技术似乎适用于直接、快速且可靠地监测纯化合物和饮料的总抗氧化活性,并且由于能够连续操作,它允许每小时分析约30个样品,使得该分析特别适合于食品样品中总抗氧化活性的大规模筛选。