Yang Li-jun, Rochholz Gertrud
Department of Narcotics Control, Yunnan Public Security College, Kunming 650223, China.
Se Pu. 2002 May;20(3):256-8.
A reversed-phase high performance liquid chromatographic method (external standard method) was developed for the determination of zopiclone in serum. After the selective extraction with n-butyl chloride, this compound was chromatographed on a LiChroCART 125-4 column packed with LiChrospher 60 RP select B(5 microns) using acetonitrile-monopotassium phosphate (20:80, V/V) as mobile phase. The eluting compound was measured by an ultraviolet detector at 254 nm. Spiked with zopiclone of 400 micrograms/L, 1,600 micrograms/L and 6,400 micrograms/L in serum, the recoveries of zopiclone were (73.4 +/- 3.2)%, (82.2 +/- 4.1)% and (90.3 +/- 4.5)% respectively. The detection limit of the method was 15 micrograms/L. The method is simple and rapid for the determination of zopiclone in forensic toxicology.
建立了一种反相高效液相色谱法(外标法)用于测定血清中的佐匹克隆。用正丁基氯进行选择性萃取后,该化合物在填充有LiChrospher 60 RP select B(5微米)的LiChroCART 125 - 4柱上进行色谱分析,以乙腈 - 磷酸二氢钾(20:80,V/V)为流动相。洗脱的化合物用紫外检测器在254 nm处进行检测。在血清中加入浓度为400微克/升、1600微克/升和6400微克/升的佐匹克隆,佐匹克隆的回收率分别为(73.4±3.2)%、(82.2±4.1)%和(90.3±4.5)%。该方法的检测限为15微克/升。该方法用于法医毒理学中佐匹克隆的测定简单快速。