Suppr超能文献

鸡眼中视网膜图像质量的双程测量。

Double-pass measurement of retinal image quality in the chicken eye.

作者信息

Coletta Nancy J, Marcos Susana, Wildsoet Christine, Troilo David

机构信息

New England College of Optometry, Boston, Massachusetts 02115, USA.

出版信息

Optom Vis Sci. 2003 Jan;80(1):50-7. doi: 10.1097/00006324-200301000-00008.

Abstract

PURPOSE

The chicken, Gallus gallus domesticus, is used as an animal model to study the development of refractive error. Although vision is important in determining the eye's refractive state, relatively little is known about the retinal image quality of the chicken eye. An objective double-pass technique was used to measure the optical quality of the eyes of White Leghorn chickens.

METHODS

Measurements were made on 21 eyes of six untreated birds and eight experimental birds that were members of a study of refractive development. Ages ranged from 3 to 6 weeks, and refractions ranged from -1.29 to +0.58 D in the untreated eyes and -4.58 to +10.17 D in the experimental eyes. The measurements were made under general anesthesia combined with either cycloplegia or ciliary nerve section. Proper optical alignment of the eye was achieved with the aid of a TV monitor, CCD camera, and an infrared source. A 543-nm laser point source was focused on the retina, and the double-pass aerial image was collected by a high-resolution CCD camera. Refractive errors were corrected with trial lenses, using a bracketing method to optimize the retinal images. Both the full width at half-maximum of the double-pass aerial image and the single-pass modulation transfer function were used as objective estimates of the optical quality.

RESULTS

The mean full width at half-maximum value in eyes of the untreated birds was 1.60 min arc for a 4.50-mm mean pupil diameter. Optical quality tended to be worse in the experimental myopic eyes.

CONCLUSIONS

The optical quality of the chicken eye measured under monochromatic conditions meets or may even exceed the neural limits of spatial acuity based on anatomical estimates of ganglion cell spacing. The data also suggest that optical quality is worse in myopic eyes, which is consistent with studies of human eyes.

摘要

目的

家鸡(Gallus gallus domesticus)被用作研究屈光不正发展的动物模型。虽然视觉在决定眼睛的屈光状态方面很重要,但对于鸡眼的视网膜图像质量却知之甚少。采用一种客观的双程技术来测量白来航鸡眼睛的光学质量。

方法

对6只未处理鸡和8只实验鸡的21只眼睛进行测量,这些鸡是屈光发育研究的对象。年龄范围为3至6周,未处理眼睛的屈光度范围为-1.29至+0.58 D,实验眼睛的屈光度范围为-4.58至+10.17 D。测量在全身麻醉联合睫状肌麻痹或睫状神经切断的情况下进行。借助电视监视器、CCD相机和红外光源实现眼睛的正确光学对准。将一个543 nm的激光点光源聚焦在视网膜上,并用高分辨率CCD相机收集双程空中图像。使用试镜矫正屈光不正,采用括弧法优化视网膜图像。双程空中图像的半高全宽和单程调制传递函数均用作光学质量的客观评估指标。

结果

对于平均瞳孔直径为4.50 mm的未处理鸡的眼睛,平均半高全宽值为1.60分弧度。实验性近视眼的光学质量往往较差。

结论

在单色条件下测量的鸡眼光学质量达到甚至可能超过基于神经节细胞间距的解剖学估计的空间敏锐度的神经学极限。数据还表明近视眼的光学质量较差,这与对人眼的研究一致。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验