Toftegaard Nielsen T
Scand J Clin Lab Invest. 1976 Oct;36(6):513-9.
A method for determination of citrate in serum and urine using citrate lyase is described. The influence of pH, zinc, magnesium, and calcium ions on the reaction velocity is studied. Citrate lyase activity is found rather insensitive to variations in pH round the pH-optimum at 8.2. Zinc ions activate the reactions. The optimal concentration of zinc ions in the reaction mixture is found to depend on the calcium concentration of samples. Perchloric acid is used for precipitation of proteins. The perchloric ion inhibits the reaction, and a procedure for removing perchlorate is given. Sensitivity of analysis is 0.005 mmo1/1 for serum and urine samples, respectively. No contamination of citrate lyase is found, and therefore addition of lactate dehydrogenase is considered unneccessary.
描述了一种使用柠檬酸裂解酶测定血清和尿液中柠檬酸盐的方法。研究了pH、锌、镁和钙离子对反应速度的影响。发现柠檬酸裂解酶活性在pH 8.2的最适pH附近对pH变化相当不敏感。锌离子激活反应。发现反应混合物中锌离子的最佳浓度取决于样品的钙浓度。高氯酸用于沉淀蛋白质。高氯酸根离子抑制反应,并给出了去除高氯酸根的方法。血清和尿液样品的分析灵敏度分别为0.005 mmol/L。未发现柠檬酸裂解酶受到污染,因此认为无需添加乳酸脱氢酶。