Goyen Mathias, Herborn Christoph U, Kröger Knut, Lauenstein Thomas C, Debatin Jörg F, Ruehm Stefan G
Department of Diagnostic and Interventional Radiology, University Hospital Essen, Hufelandstrasse 55, 45122 Essen, Germany.
Radiology. 2003 Apr;227(1):277-82. doi: 10.1148/radiol.2271020488. Epub 2003 Feb 19.
In 100 consecutive patients with peripheral vascular disease whole-body three-dimensional magnetic resonance (MR) angiography was performed by using the rolling table platform system with a 1.5-T MR unit and five three-dimensional MR angiographic data sets during 72 seconds (0.2 mol per kilogram of body weight of gadobenate dimeglumine). Apart from the proved peripheral vascular disease, additional clinically relevant disease was found in 33 segments in 25 patients as follows: renal arterial narrowing (n = 15), carotid arterial stenosis (n = 12), subclavian arterial stenosis (n = 2), and abdominal aortic aneurysms (n = 4). Confirmatory studies performed in 11 patients in this study revealed no false-positive or false-negative findings at examination.
对100例连续性外周血管疾病患者,使用1.5-T磁共振(MR)单元和滚动检查床平台系统,在72秒内(使用钆贝葡胺0.2摩尔/千克体重)采集了5组三维MR血管造影数据集,进行全身三维磁共振血管造影。除了已确诊的外周血管疾病外,在25例患者的33个节段中还发现了其他具有临床意义的疾病,如下:肾动脉狭窄(n = 15)、颈动脉狭窄(n = 12)、锁骨下动脉狭窄(n = 2)和腹主动脉瘤(n = 4)。本研究中对11例患者进行的验证性检查未发现检查时有假阳性或假阴性结果。