动脉粥样硬化疾病:采用具有32个接收通道的磁共振系统和全身表面线圈技术进行全身心血管成像——初步临床结果。

Atherosclerotic disease: whole-body cardiovascular imaging with MR system with 32 receiver channels and total-body surface coil technology--initial clinical results.

作者信息

Fenchel Michael, Scheule Albertus M, Stauder Norbert I, Kramer Ulrich, Tomaschko Katrin, Nägele Thomas, Bretschneider Christiane, Schlemmer Heinz-Peter, Claussen Claus D, Miller Stephan

机构信息

Department of Diagnostic Radiology, Eberhard-Karls-University, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany.

出版信息

Radiology. 2006 Jan;238(1):280-91. doi: 10.1148/radiol.2381041532. Epub 2005 Nov 22.

Abstract

In this prospective study, the feasibility of a comprehensive cardiovascular imaging protocol with a dedicated whole-body 1.5-T magnetic resonance (MR) imager with 32 receiver channels in 34 patients with peripheral arterial occlusive disease was evaluated. Informed consent and institutional review board approval were obtained. Three-dimensional MR angiographic data sets were acquired with adapted injection protocol. Cardiac functional imaging and delayed-enhancement imaging were performed, as were fluid-attenuated inversion-recovery imaging of the brain and time-of-flight MR angiography of the intracranial blood vessels. Sensitivity and specificity for depiction of significant vascular stenosis (> 70%) were 96%, with conventional digital subtraction angiography as the standard. Substantial microangiopathic tissue alterations (n = 4) and/or cerebral infarction (n = 4) were diagnosed in seven patients. In seven patients, subendocardial or transmural delayed enhancement was detected in corresponding regions, indicating prior myocardial infarction. Previously unknown findings diagnosed with MR imaging required midterm follow-up or therapy in 24 patients, whereas change of therapy or immediate treatment was necessary in three. For patients suspected of having systemic atherosclerotic disease, comprehensive risk assessment is feasible within 30 minutes.

摘要

在这项前瞻性研究中,评估了使用具有32个接收通道的专用全身1.5-T磁共振(MR)成像仪对34例外周动脉闭塞性疾病患者进行综合心血管成像方案的可行性。获得了知情同意书并得到机构审查委员会的批准。采用适应性注射方案采集三维MR血管造影数据集。进行了心脏功能成像和延迟强化成像,以及脑部液体衰减反转恢复成像和颅内血管时间飞跃MR血管造影。以传统数字减影血管造影为标准,对显著血管狭窄(>70%)的描绘的敏感性和特异性为96%。7例患者被诊断出存在大量微血管病变组织改变(n = 4)和/或脑梗死(n = 4)。7例患者在相应区域检测到心内膜下或透壁延迟强化,提示既往心肌梗死。24例通过MR成像诊断出的此前未知的发现需要中期随访或治疗,而3例则需要改变治疗方案或立即治疗。对于疑似患有全身性动脉粥样硬化疾病的患者,在30分钟内进行综合风险评估是可行的。