Incorporating leaf transmission and head scatter corrections into step-and-shoot leaf sequences for IMRT.

作者信息

Yang Yong, Xing Lei

机构信息

Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA 94305, USA.

出版信息

Int J Radiat Oncol Biol Phys. 2003 Mar 15;55(4):1121-34. doi: 10.1016/s0360-3016(02)04417-6.

DOI:10.1016/s0360-3016(02)04417-6
PMID:12605992
Abstract

PURPOSE

Leaf transmission and head scatter are two important factors that influence intensity-modulated radiation therapy (IMRT) delivery and should be correctly taken into account when generating multileaf collimator (MLC) sequences. Significant discrepancies between the desired and delivered intensity profiles could otherwise result. The purpose of this article is to propose a reliable algorithm to minimize the dosimetric effects caused by the two factors in step-and-shoot mode.

MATERIALS AND METHODS

The goal of the algorithm is to minimize the difference between the desired fluence map and the fluence map actually delivered. For this purpose, an error function, defined as the least-square difference between the desired and the delivered fluence maps, is introduced. The effects of transmission and head scatter are minimized by adjusting the fractional monitor units (MUs) in the initial MLC sequences, created by using the desired fluence map without inclusion of the contributions from the two factors. Computationally, a downhill simplex optimization method is used to minimize the error function with respect to the fractional MUs. A three-source model is used to evaluate the relative head scatter distribution for each segment at the beginning of the calculation. The algorithm has been assessed by comparing the dose distributions delivered by the corrected leaf sequence files and the theoretic predication, calculated by Monte Carlo simulation using the desired fluence maps, for an intuitive test field and several clinical IMRT cases.

RESULTS

The deviations between the desired fluence maps and those calculated using the corrected leaf sequence files are <0.3% of the maximum MU for the test field and <1.0% for the clinical IMRT cases. The experimental data show that both absolute and relative dose distributions delivered by the corrected leaf sequences agree with the desired ones within 2.5% of the maximum dose or 2 mm in high-dose gradient regions. Compared with the results obtained by using the leaf sequences in which only the transmission or none of the two effects is corrected, significant improvements in the fluence and dose distributions have been observed.

CONCLUSIONS

Transmission and head scatter play important roles in the dosimetric behavior of IMRT delivery. A larger error may result if only one factor is considered because of the opposite effects of the two factors. We noted that the influence of the two effects is more pronounced in absolute dose than in the relative dose. The algorithm proposed in this work accurately corrects for these two effects in step-and-shoot delivery and provides a reliable tool for clinical IMRT application.

摘要

相似文献

1
Incorporating leaf transmission and head scatter corrections into step-and-shoot leaf sequences for IMRT.
Int J Radiat Oncol Biol Phys. 2003 Mar 15;55(4):1121-34. doi: 10.1016/s0360-3016(02)04417-6.
2
Independent dosimetric calculation with inclusion of head scatter and MLC transmission for IMRT.用于调强放射治疗(IMRT)的包含头部散射和多叶准直器(MLC)透射的独立剂量计算
Med Phys. 2003 Nov;30(11):2937-47. doi: 10.1118/1.1617391.
3
Dependence of fluence errors in dynamic IMRT on leaf-positional errors varying with time and leaf number.动态调强放射治疗中注量误差随时间和叶片序号变化对叶片位置误差的依赖性。
Med Phys. 2003 Oct;30(10):2736-49. doi: 10.1118/1.1598674.
4
A method for photon beam Monte Carlo multileaf collimator particle transport.一种用于光子束蒙特卡罗多叶准直器粒子输运的方法。
Phys Med Biol. 2002 Sep 7;47(17):3225-49. doi: 10.1088/0031-9155/47/17/312.
5
Enhancement of IMRT delivery through MLC rotation.通过多叶准直器旋转增强调强放射治疗的实施
Phys Med Biol. 2002 Nov 21;47(22):3997-4017. doi: 10.1088/0031-9155/47/22/307.
6
A topographic leaf-sequencing algorithm for delivering intensity modulated radiation therapy.一种用于实施调强放射治疗的断层叶片排序算法。
Med Phys. 2006 Aug;33(8):2751-6. doi: 10.1118/1.2216876.
7
Analytic IMRT dose calculations utilizing Monte Carlo to predict MLC fluence modulation.利用蒙特卡罗方法进行解析调强放疗剂量计算以预测多叶准直器注量调制。
Med Phys. 2006 Apr;33(4):828-39. doi: 10.1118/1.2178449.
8
The impact of fluctuations in intensity patterns on the number of monitor units and the quality and accuracy of intensity modulated radiotherapy.强度模式波动对调强放射治疗的监测单位数量以及质量和准确性的影响。
Med Phys. 2000 Jun;27(6):1226-37. doi: 10.1118/1.599000.
9
Real-time verification of multileaf collimator-driven radiotherapy using a novel optical attenuation-based fluence monitor.使用新型基于光学衰减的剂量计对多叶准直器驱动的放射治疗进行实时验证。
Med Phys. 2011 Mar;38(3):1459-67. doi: 10.1118/1.3549766.
10
A quantitative study of IMRT delivery effects in commercial planning systems for the case of oesophagus and prostate tumours.针对食管癌和前列腺癌病例,在商业治疗计划系统中对调强放射治疗(IMRT)实施效果的定量研究。
Br J Radiol. 2006 May;79(941):401-8. doi: 10.1259/bjr/91588055.

引用本文的文献

1
Multileaf Collimator Modeling and Commissioning for Complex Radiation Treatment Plans Using 2-Dimensional (2D) Diode Array MapCHECK2.使用二维(2D)二极管阵列MapCHECK2对复杂放射治疗计划进行多叶准直器建模与调试
Technol Cancer Res Treat. 2024 Jan-Dec;23:15330338231225864. doi: 10.1177/15330338231225864.
2
Rapid direct aperture optimization via dose influence matrix based piecewise aperture dose model.基于剂量影响矩阵的分段孔径剂量模型的快速直接孔径优化。
PLoS One. 2018 May 23;13(5):e0197926. doi: 10.1371/journal.pone.0197926. eCollection 2018.
3
Multisource modeling of flattening filter free (FFF) beam and the optimization of model parameters.
多源模型化自由浮动滤过(FFF)射束和模型参数优化。
Med Phys. 2011 Apr;38(4):1931-42. doi: 10.1118/1.3560426.
4
Using total-variation regularization for intensity modulated radiation therapy inverse planning with field-specific numbers of segments.使用全变差正则化进行具有特定射野子段数量的调强放射治疗逆向计划
Phys Med Biol. 2008 Dec 7;53(23):6653-72. doi: 10.1088/0031-9155/53/23/002. Epub 2008 Nov 7.