The original SISI test (Jerger, Shedd and Harford) is described in German language. Modifications of various authors are cited. The results of SISI test with 16 persons demanding monetary compensation for hearing loss are tabulated. 18 ears seemed free from non-organic overlay. 12 of those ears gave SISI scores more than 70%. Functional discrepancies wer observed in 13 ears. Only in one of them a maximum SISI score of 25% was presented. All other non-organic ears gave lower ratings, 0% in most cases. Increments of 5 dB were not responded with 5 ears. In one case of unilateral non-organic loss SISI scores were high in the normal and low in the aggravating ear. It is suggested therefore, that low SISI ratings should arise suspicion of non-organic problems, besides of retrocochlear site.
最初的短增量敏感指数测试(耶格、谢德和哈福德)用德语进行了描述。引用了不同作者的修改方法。列出了16名因听力损失要求金钱赔偿者的短增量敏感指数测试结果。18只耳朵似乎没有非器质性叠加。其中12只耳朵的短增量敏感指数得分超过70%。在13只耳朵中观察到功能差异。其中只有一只耳朵的最大短增量敏感指数得分为25%。所有其他非器质性耳朵的评分较低,大多数情况下为0%。5只耳朵对5分贝的增量没有反应。在一例单侧非器质性听力损失中,正常耳朵的短增量敏感指数得分高,加重耳朵的得分低。因此,有人建议,除了蜗后部位外,低短增量敏感指数评分应引起对非器质性问题的怀疑。