Kiessling J
Laryngol Rhinol Otol (Stuttg). 1979 Nov;58(11):842-7.
The reliability of SISI Test for audiological evaluation of hearing impairment is investigated basing on audiometric findings of 604 subjects. In addition to the dependence of SISI scores on the age of the subjects the influence of sound pressure level and frequency is discussed. Comparing SISI results with those of other differential diagnostic tests we find that SISI test tends to indicate haircell lesions even though other tests exhibit a different site of the lesion. Particularly in cases of uncertain, complex hearing impairments (noise plus other causes) SISI test frequently shows false-positive results. Therefore SISI scores should be interpreted carefully especially with regard to legal examination of noise induced hearing impairment.
基于604名受试者的听力测定结果,对用于听力障碍听力评估的短增量敏感指数(SISI)测试的可靠性进行了研究。除了SISI分数与受试者年龄的相关性外,还讨论了声压级和频率的影响。将SISI测试结果与其他鉴别诊断测试结果进行比较,我们发现SISI测试倾向于表明毛细胞病变,即使其他测试显示病变部位不同。特别是在不确定的复杂听力障碍(噪声加其他原因)的情况下,SISI测试经常出现假阳性结果。因此,尤其是在对噪声性听力损伤进行法律检查时,应谨慎解释SISI分数。