Jeffcoat Marjorie K, McGlumphy Edwin A, Reddy Michael S, Geurs Nico C, Proskin Howard M
Department of Periodontology, University of Alabama School of Dentistry, Birmingham, Alabama 35294-0007, USA.
Int J Oral Maxillofac Implants. 2003 May-Jun;18(3):406-10.
The purpose of this study was to compare the success of hydroxyapatite (HA) -coated and machined titanium (Ti) implants in a 5-year randomized, controlled clinical trial conducted at 2 centers.
Each of 120 edentulous patients received HA-coated threaded, HA-coated cylindric, and machined Ti threaded implants in a randomized design using 5 or 6 implants. Digital radiographs allowed for yearly measurements of bone loss. Calibrated clinicians also measured mobility, Gingival Index, Plaque Index, probing depth, and recession. A Kaplan-Meier analysis was used to compare the proportion of ailing implants (defined as less than 2 mm of alveolar bone loss over 5 years) for each type of implant design. The criteria employed to assess implant outcome included the need for successful implants to lose less than 2 mm of bone support over the 5 years following placement of the prosthesis.
This analysis revealed that 95.2% of machined Ti threaded implants and 97.92% of HA-coated threaded implants were successful, while 99.0% of HA-coated cylindric implants experienced less than 2 mm of bone loss (P < .06).
All types of implants placed in this study had success rates above 95%.
Over 5 years, the success rate tended to favor HA-coated implants.
本研究的目的是在两个中心进行的一项为期5年的随机对照临床试验中,比较羟基磷灰石(HA)涂层和机械加工钛(Ti)种植体的成功率。
120名无牙患者中的每一位都以随机设计接受了HA涂层螺纹种植体、HA涂层圆柱形种植体和机械加工Ti螺纹种植体,使用5或6颗种植体。数字化X线片可用于每年测量骨吸收情况。经过校准的临床医生还测量了松动度、牙龈指数、菌斑指数、探诊深度和牙龈退缩情况。采用Kaplan-Meier分析比较每种种植体设计中出现问题的种植体(定义为5年内牙槽骨吸收小于2mm)的比例。评估种植体结果所采用的标准包括成功的种植体在义齿植入后5年内骨支持丧失少于2mm。
该分析显示,95.2%的机械加工Ti螺纹种植体和97.92%的HA涂层螺纹种植体成功,而99.0%的HA涂层圆柱形种植体骨吸收小于2mm(P < 0.06)。
本研究中植入的所有类型种植体的成功率均高于95%。
在5年时间里,成功率倾向于支持HA涂层种植体。