Suppr超能文献

[使用微量分析法测定血液中的pH值和气体:在4℃储存一小时的影响。一项在大鼠身上的研究]

[The measurement of pH and gases in the blood using microanalysis: the effect of storage at 4 degrees C for an hour. A study in the rat].

作者信息

Gaudy J H, Sicard J F, Quignon M

机构信息

Laboratoire d'Anesthésiologie, Faculté de médecine Saint-Antoine, Paris, France.

出版信息

Can J Anaesth. 1992 Oct;39(8):786-90. doi: 10.1007/BF03008289.

Abstract

The effects of one hour storage at 4 degrees C on micro blood gas samples (150 microliters) were studied for a wide range of values (pH: 7.11-7.58; PCO2: 26-97 mmHg; PO2: 31-503 mmHg) in 20 rats with indwelling carotid artery catheters. Blood gas values were modified by varying the composition of inspired gases: normoxia, hypocapnic hypoxia, hyperoxia, hypercapnia (in this case eight animals were anaesthetized with halothane 1.1%). One hundred and eight double micro-samples were taken. For each double sample, one was analysed immediately (H0) and compared with the second sample after one hr storage at 4 degrees C (H1). The Bland and Altman method was used for the statistical analysis of results. After one hr storage at 4 degrees C, the PCO2 was slightly higher than at H0 (mean difference +/- SD: +1.08 +/- 1.7 mmHg) and arterial pH was slightly lower (mean difference +/- SD: -0.016 upH +/- 0.011 upH). These results show that for these two variables, in the range studied, one hour storage at 4 degrees C had little effect. In contrast, for arterial PO2 the mean difference between all measurements between H1 and H0 was -17 +/- 25 mmHg. If results lower than 200 mmHg (56 double samples) are considered separately, the mean difference between values at H1 and H0 was only -0.98 +/- 5.3 mmHg. For PaO2 greater than 200 mmHg (52 double samples), the mean difference was -34 +/- 26.3 mmHg; this may be due to low reproducibility of measurements of elevated PO2 levels and to the effects of cellular metabolism.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

对20只留置颈动脉导管的大鼠,研究了在4℃下储存1小时对微量血气样本(150微升)的影响,样本涵盖了广泛的数值范围(pH:7.11 - 7.58;PCO₂:26 - 97 mmHg;PO₂:31 - 503 mmHg)。通过改变吸入气体的成分来改变血气值:常氧、低碳酸血症性低氧、高氧、高碳酸血症(在这种情况下,8只动物用1.1%的氟烷麻醉)。共采集了108对微量样本。对于每一对样本,一个立即进行分析(H0),并与在4℃下储存1小时后的第二个样本(H1)进行比较。采用Bland和Altman方法对结果进行统计分析。在4℃下储存1小时后,PCO₂略高于H0时的值(平均差值±标准差:+1.08±1.7 mmHg),动脉pH略低(平均差值±标准差:-0.016ΔpH±0.011ΔpH)。这些结果表明,对于这两个变量,在所研究的范围内,4℃下储存1小时影响很小。相比之下,动脉PO₂在H1和H0之间所有测量值的平均差值为-17±25 mmHg。如果单独考虑低于200 mmHg的结果(56对样本),H1和H0时的值之间的平均差值仅为-0.98±

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验