• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[Noninvasive estimation of the pulmonary artery pressures in patent ductus arteriosus with continuous-wave Doppler echocardiography].

作者信息

Zhang Y, Ge Z M, Fan D S

机构信息

Department of Cardiology, Affiliated Hospital, Shandong Medical University, Jinan.

出版信息

Zhonghua Nei Ke Za Zhi. 1992 Oct;31(10):614-6, 657.

PMID:1306452
Abstract

To develop a new method for noninvasive measuring of the pulmonary artery pressure (PAP) in patient ductus arteriosus (PDA), left and right heart catheterization (Cath) and continuous-wave Doppler echocardiography (CWD) were performed simultaneously in 30 cases with PDA. The results showed that there was high correlation of the systolic peak pressure gradient (delta pp), the end-diastolic pressure gradient (delta Pd) and the mean pressure gradient (delta Pm), across PDA measured with the two techniques (r = 0.99, 0.96 and 0.98, respectively). The CWD-derived pulmonary artery systolic (PASP), diastolic (PADP) and mean (PAMP) pressure, which were estimated by subtracting delta Pp, delta Pd and delta Pm from the brachial artery systolic, diastolic and mean pressure, correlated well with the corresponding PAP measured with Cath (r = 0.92, 0.89 and 0.94, respectively). It is concluded that CWD offers a reliable technique for estimating shunt pressure gradients and PAP in patients with PDA.

摘要

相似文献

1
[Noninvasive estimation of the pulmonary artery pressures in patent ductus arteriosus with continuous-wave Doppler echocardiography].
Zhonghua Nei Ke Za Zhi. 1992 Oct;31(10):614-6, 657.
2
[Determination of pressure gradient across patent ductus arteriosus with simultaneous continuous wave Doppler and catheterization methods and non-invasive estimation of pulmonary artery pressure].
Zhonghua Nei Ke Za Zhi. 1991 Sep;30(9):550-3, 594.
3
[Estimation of systolic pulmonary artery pressure with continuous wave Doppler pressure gradient method: a simultaneous Doppler and catheter correlative study].
Zhonghua Nei Ke Za Zhi. 1990 May;29(5):290-2, 317-8.
4
[Measurement by Doppler echocardiography of the pulmonary arterial pressure in children with ductus arteriosus. Simultaneous Doppler and hemodynamic study].[应用多普勒超声心动图测量动脉导管未闭患儿的肺动脉压。多普勒与血流动力学同步研究]
Arch Mal Coeur Vaiss. 1986 May;79(5):719-24.
5
[Estimation of pulmonary vascular resistance by Doppler echocardiography with simultaneous catheterization].[经多普勒超声心动图与同步心导管检查评估肺血管阻力]
Zhonghua Xin Xue Guan Bing Za Zhi. 1990 Aug;18(4):204-6, 253.
6
Reliability and accuracy of measurement of transductal gradient by Doppler ultrasound.经导管梯度的多普勒超声测量的可靠性与准确性
Int J Cardiol. 1993 Jun 15;40(1):35-43. doi: 10.1016/0167-5273(93)90228-9.
7
Validation of Doppler-derived pulmonary arterial pressure in patients with ductus arteriosus under different hemodynamic states.不同血流动力学状态下动脉导管未闭患者中多普勒衍生肺动脉压的验证
Circulation. 1987 Nov;76(5):1081-91. doi: 10.1161/01.cir.76.5.1081.
8
[Non-invasive assessment of the peak pressure gradient between the aorta and pulmonary artery in patent ductus arteriosus].
J Cardiol. 1987 Jun;17(2):353-60.
9
Evaluation of pulmonary arterial pressure by Doppler colour flow mapping in patients with a ductus arteriosus.应用多普勒彩色血流图评估动脉导管未闭患者的肺动脉压
Br Heart J. 1990 May;63(5):295-9. doi: 10.1136/hrt.63.5.295.
10
Noninvasive Doppler echocardiographic evaluation of shunt flow dynamics of the ductus arteriosus.动脉导管分流血流动力学的无创性多普勒超声心动图评估
Circulation. 1987 Jun;75(6):1146-53. doi: 10.1161/01.cir.75.6.1146.