Suppr超能文献

[用高压液相色谱法测定胺碘酮和去乙基胺碘酮的血浆浓度。初步经验]

[Determination of plasma concentration of amiodarone and desethylamiodarone with high pressure liquid chromatography. Preliminary experience].

作者信息

Saavedra I, Ortiz M, Gaete L, Asenjo R, Biagini L

机构信息

Departamento de Bioquímica y Química, Facultad de Medicina, Universidad de Chile, Santiago.

出版信息

Rev Med Chil. 1992 Jun;120(6):661-5.

PMID:1341797
Abstract

A simple specific and sensitive high pressure liquid chromatography method (HPLC) to measure amiodarone and desethylamiodarone is described. The plasma sample is deproteinized with acetonitrile and a 50 ul aliquote run in the HPLC system with reverse phase column (C-18). Methanol-ammonium hydroxide is used to separate and spectrophotometric measurements are read at 254 nm.95% of the drug present in plasma is extracted with this method, with a sensitivity of 0.03 ug/ml and a day to day variation under 3%. Preliminary measurements were analyzed in 14 subjects receiving amiodarone for treatment of supraventricular arrhythmia. With a mean dose of 267 +/- 116 (SD) mg/day, plasma levels of 1.3 +/- 0.6 ug.ml for amiodarone and 0.9 +/- 0.5 mg/ml for desethylamiodarone were obtained.

摘要

本文描述了一种用于测定胺碘酮和去乙基胺碘酮的简单、特异且灵敏的高压液相色谱法(HPLC)。血浆样本用乙腈进行蛋白沉淀,取50微升等分试样注入配备反相柱(C-18)的HPLC系统中。使用甲醇-氢氧化铵进行分离,并在254纳米处进行分光光度测量。用该方法可提取出血浆中95%的药物,灵敏度为0.03微克/毫升,每日变化在3%以下。对14名接受胺碘酮治疗室上性心律失常的受试者进行了初步测量。平均剂量为267±116(标准差)毫克/天,胺碘酮的血浆水平为1.3±0.6微克/毫升,去乙基胺碘酮的血浆水平为0.9±0.5毫克/毫升。