Suppr超能文献

眼压的昼夜变化:690条昼夜眼压曲线分析

Diurnal intraocular pressure variations: an analysis of 690 diurnal curves.

作者信息

David R, Zangwill L, Briscoe D, Dagan M, Yagev R, Yassur Y

机构信息

Department of Ophthalmology, Soroka Medical Center, Beer Sheva, Israel.

出版信息

Br J Ophthalmol. 1992 May;76(5):280-3. doi: 10.1136/bjo.76.5.280.

Abstract

Out of a total of 2272 diurnal curves (DC) of intraocular pressure (IOP) obtained from 1178 patients 690 first curves of the right eye of all patients were analysed. For each DC there were 4-6 IOP readings taken between 8 am and 6.30 pm of the same day. The patients' diagnosis, age, sex, type of IOP lowering medication, diabetes, and the calendar month of the year were recorded. In 40% of cases the highest IOP was found at the earliest morning measurement with some 65% of peaks occurring before noon. The lowest IOP measurement showed no specific predilection for any particular time of the day. These findings were true for all diagnosis groups. The mean range of IOP fluctuation during the DC was 5.0 mm Hg in normals, 5.8 mm Hg in patients with open angle glaucoma (OAG), and 6.8 mm Hg in patients with ocular hypertension (OHT). Patients treated with timolol had a lower mean IOP fluctuation range than those on other types of IOP lowering treatment. No association was found between all other parameters examined and the diurnal IOP distribution.

摘要

在从1178名患者获得的总共2272条眼压(IOP)日曲线(DC)中,分析了所有患者右眼的690条首次曲线。对于每条DC,在同一天上午8点至下午6点30分之间进行4至6次IOP读数。记录患者的诊断、年龄、性别、降低眼压药物的类型、糖尿病以及一年中的日历月份。在40%的病例中,最早的早晨测量发现眼压最高,约65%的峰值出现在中午之前。最低眼压测量值在一天中的任何特定时间都没有表现出特定的偏好。所有诊断组均是如此。正常眼压者DC期间眼压波动的平均范围为5.0 mmHg,开角型青光眼(OAG)患者为5.8 mmHg,高眼压症(OHT)患者为6.8 mmHg。使用噻吗洛尔治疗的患者平均眼压波动范围低于使用其他类型降低眼压治疗的患者。在所检查的所有其他参数与日间眼压分布之间未发现关联。

相似文献

5
Individual variability in the diurnal intraocular pressure curve.昼夜眼压曲线的个体差异。
Ophthalmology. 1993 Jun;100(6):940-4. doi: 10.1016/s0161-6420(93)31551-4.

引用本文的文献

3
Corneal biomechanics and diagnostics: a review.角膜生物力学与诊断:综述
Int Ophthalmol. 2024 Mar 13;44(1):132. doi: 10.1007/s10792-024-03057-1.

本文引用的文献

3
Diurnal intraocular pressure variation in a glaucoma screening program.青光眼筛查项目中的日间眼压波动
Arch Ophthalmol. 1968 Dec;80(6):714-7. doi: 10.1001/archopht.1968.00980050716006.
5
Application of a self-tonometer to home tonometry.自眼压计在家庭眼压测量中的应用。
Arch Ophthalmol. 1986 Jan;104(1):49-53. doi: 10.1001/archopht.1986.01050130059020.
7
Diurnal variation of intraocular pressure in primary open-angle glaucoma.
Am J Ophthalmol. 1975 Apr;79(4):557-66. doi: 10.1016/0002-9394(75)90792-8.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验