• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

CAPD bag changing with integrated disconnect system gives lower incidence of peritonitis than with UV-box system.

作者信息

Wikdahl A M, Granbom L, Stegmayr B G

机构信息

Department of Internal Medicine, University Hospital, Umeå, Sweden.

出版信息

Adv Perit Dial. 1992;8:276-80.

PMID:1361805
Abstract

UNLABELLED

The use of a UV-box disconnect system reduces the incidence of peritonitis as compared with manual exchanges. An integrated disconnect system (IDS) also gives good results. See Figure 1. From 1988-1991, we prospectively compared two groups of patients using either a UV-box disconnect system (Baxter, n = 18, mean age 64, range 28-75 yrs) or an IDS (Baxter, n = 25, mean age 53, range 30-78). The Tenckhoff catheter had been inserted by the same technique in all patients, and the training program and nursing care were also identical. Since many younger patients preferred IDS and refused randomization, age was significantly lower in the IDS group. All peritonitis episodes (PER) were registered. Excluded from calculations of PER were episodes most probably not due to failure in connective device: PER after incidental penetration of the dialysis bags, deep penetrating tunnel infections and in the direct course of abdominal surgery.

RESULTS

There were significantly fewer months with PER (one month = 1 PER; Chi-2 = 6.45, p < 0.05) in patients using the IDS (3 PER/269 months) compared with those using the UV-box system (15 PER/355 months). The IDS was requested mainly by younger patients, while some older patients found it to be too complicated.

CONCLUSION

The integrated disconnect system is especially acceptable by younger patients, and patients using the IDS show a low incidence of peritonitis.

摘要

相似文献

1
CAPD bag changing with integrated disconnect system gives lower incidence of peritonitis than with UV-box system.
Adv Perit Dial. 1992;8:276-80.
2
Peritonitis incidence on a disconnect CAPD-system with or without the use of iodine clamp shields.
Adv Perit Dial. 1994;10:150-3.
3
A randomized multicenter trial to evaluate the effects of UV-Flash system on peritonitis rates in CAPD.
Adv Perit Dial. 1992;8:313-5.
4
Prevention of peritonitis with disconnect systems in CAPD: a randomized controlled trial. The Mexican Nephrology Collaborative Study Group.持续性非卧床腹膜透析中使用断开连接系统预防腹膜炎:一项随机对照试验。墨西哥肾脏病协作研究组。
Kidney Int. 1998 Dec;54(6):2123-8. doi: 10.1046/j.1523-1755.1998.00190.x.
5
Significant reduction of peritonitis rate by the use of Twin-bag system in a Canadian regional CAPD program.在加拿大一个地区性持续性非卧床腹膜透析项目中,使用双袋系统可显著降低腹膜炎发生率。
Adv Perit Dial. 1992;8:223-6.
6
Improved training techniques and UltraBag system resulted in lowered peritonitis rate in an inner-city population.
Adv Perit Dial. 1995;11:208-9.
7
Reduced risk for peritonitis in CAPD with the use of a UV connector box.使用紫外线连接盒可降低持续性非卧床腹膜透析患者腹膜炎的风险。
Perit Dial Int. 1991;11(2):128-30.
8
Fivefold reduction in peritonitis using a multifaceted continuous quality initiative program.通过多方面持续质量改进计划,腹膜炎发生率降低了五倍。
Adv Perit Dial. 2003;19:202-5.
9
Use of pure bicarbonate-buffered peritoneal dialysis fluid reduces the incidence of CAPD peritonitis.使用纯碳酸氢盐缓冲腹膜透析液可降低持续性非卧床腹膜透析相关性腹膜炎的发生率。
Nephrol Dial Transplant. 2007 Jun;22(6):1703-8. doi: 10.1093/ndt/gfl848. Epub 2007 Apr 3.
10
PD-related infections of standard and different disconnect systems.
Adv Perit Dial. 1994;10:214-7.

引用本文的文献

1
Outcomes of patients who participate in randomized controlled trials compared to similar patients receiving similar interventions who do not participate.参与随机对照试验的患者与接受类似干预但未参与试验的类似患者的结局比较。
Cochrane Database Syst Rev. 2008 Jul 16;2008(3):MR000009. doi: 10.1002/14651858.MR000009.pub4.
2
Systematic review to determine whether participation in a trial influences outcome.进行系统评价以确定参与试验是否会影响结果。
BMJ. 2005 May 21;330(7501):1175. doi: 10.1136/bmj.330.7501.1175.