Izumi W, Murai M, Komatsu H, Ishimitsu S, Okada S
Eisei Shikenjo Hokoku. 1992(110):113-6.
Prednisolone was tested for preparation of the "Prednisolone Reference Standard (Control 911)". The quality of raw material was examined and compared with the previous Reference Standard (Control 872). Analytical data obtained were as follows: loss on drying, 0.10%; melting point, 233.2 degrees C (decomposition); optical rotation, [alpha]20D+98.77 degrees; UV spectrum, lambda max = 243nm; absorptivity, E1%1cm (243nm) = 413.5; IR spectrum, 1711, 1612, 1110, 888cm-1; one impurity was detected by thin-layer chromatography and high-performance liquid chromatography (HPLC), respectively; assay, 100.1% by HPLC. Based on the above results, the raw material was authorized as the Japanese Pharmacopoeia Standard (Control 911).
对泼尼松龙进行了“泼尼松龙参比标准品(对照品911)”的制备测试。对原料质量进行了检验,并与先前的参比标准品(对照品872)进行了比较。获得的分析数据如下:干燥失重0.10%;熔点233.2℃(分解);旋光度,[α]20D +98.77°;紫外光谱,λmax = 243nm;吸光度,E1%1cm(243nm)= 413.5;红外光谱,1711、1612、1110、888cm-1;分别通过薄层色谱法和高效液相色谱法(HPLC)检测到一种杂质;通过HPLC测定含量为100.1%。基于上述结果,该原料被批准为日本药典标准品(对照品911)。