WHITTEMBURY G, WINDHAGER E E
J Gen Physiol. 1961 Mar;44(4):679-87. doi: 10.1085/jgp.44.4.679.
Transtubular and peritubular face electrical potential differences (P.D.) of the proximal tubules of the kidney of the amphibian Necturus maculosus have been measured in situ. These measurements have been carried out both under normal conditions, when the tubular fluid originates in the glomerular filtrate, and under conditions when the composition of the tubular fluid has been altered using the stopped flow microperfusion technique. Under normal conditions the transtubular potential difference is 20 mv. (lumen-negative) and the P.D. across the peritubular face is 74 mv. (cell-negative). The P.D. across the luminal face is thus 54 mv. (cell-negative). This electrical asymmetry is not influenced by replacing the normal tubular fluid by NaCl, NaCl + mannitol, or by alteration in the intraluminal pH from 7 to 4. On the other hand, replacement of Na by K or choline and the addition of small amounts of DNP to the perfusate diminish this asymmetry.
对有斑泥螈肾脏近端小管的跨管和管周面电势差(P.D.)进行了原位测量。这些测量在正常条件下进行,此时管内液源自肾小球滤液;也在使用停流微量灌注技术改变管内液成分的条件下进行。正常条件下,跨管电势差为20毫伏(管腔为负),管周面的P.D.为74毫伏(细胞为负)。因此,跨腔面的P.D.为54毫伏(细胞为负)。用氯化钠、氯化钠+甘露醇替代正常管内液,或管腔内pH值从7变为4,均不影响这种电不对称性。另一方面,用钾或胆碱替代钠,以及向灌注液中添加少量二硝基苯酚会减小这种不对称性。