Abstract

The conditions required for the production of a polylysine-coated gold (PL-G) complex, which shows optimal sensitivity for the demonstration of tissue anionic sites, expressed under different conditions of pH have been investigated. Problems encountered with this complex have been compared with those found with other methods of conjugation of polylysine to colloidal gold. The performance of a bovine serum albumin (BSA)-stabilized PL-G complex was examined against other PL-G conjugates, including complexes that are commercially available, for the detection of heterogeneous glomerular anionic site populations, expressed at pH 2.5 and pH 7.0.

摘要

已对聚赖氨酸包被金(PL-G)复合物的制备条件进行了研究,该复合物对组织阴离子位点的显示具有最佳灵敏度,其在不同pH条件下表达。已将该复合物遇到的问题与聚赖氨酸与胶体金其他偶联方法中发现的问题进行了比较。针对检测在pH 2.5和pH 7.0下表达的异质性肾小球阴离子位点群体,对牛血清白蛋白(BSA)稳定的PL-G复合物与其他PL-G偶联物(包括市售复合物)的性能进行了检测。