Effect of particle size on labeling intensity in protein A-gold immunocytochemistry was studied. Catalase labeling of rat liver peroxisomes was used as a labeling model. Ultra-thin sections of Lowicryl K4M-embedded rat liver were stained for catalase with protein A-gold (pAg) probes. Five different sizes of colloidal gold probes, from 5 nm to 38 nm in diameter, were prepared. Labeling intensity decreased as the particle size of the pAg probes increased. The highest labeling was obtained by the 5-nm pAg probe and the lowest by the 38-nm pAg probe. Quantitative analysis also showed that labeling density was inversely proportional to the size of gold particles. The results suggest that the pAg probe with small gold particles has high sensitivity.

摘要

研究了粒径对蛋白A-金免疫细胞化学中标记强度的影响。以大鼠肝脏过氧化物酶体的过氧化氢酶标记作为标记模型。用蛋白A-金(pAg)探针将Lowicryl K4M包埋的大鼠肝脏超薄切片进行过氧化氢酶染色。制备了五种不同直径(5纳米至38纳米)的胶体金探针。随着pAg探针粒径的增加,标记强度降低。5纳米的pAg探针获得的标记最高,38纳米的pAg探针获得的标记最低。定量分析还表明,标记密度与金颗粒大小成反比。结果表明,具有小金颗粒的pAg探针具有高灵敏度。