Suppr超能文献

Genital tract infections associated with the intrauterine contraceptive device can be reduced by inserting the threads into the uterine cavity.

作者信息

Pap-Akeson M, Solheim F, Thorbert G, Akerlund M

机构信息

Department of Obstetrics and Gynecology, Central Hospital, Borås, Sweden.

出版信息

Br J Obstet Gynaecol. 1992 Aug;99(8):676-9. doi: 10.1111/j.1471-0528.1992.tb13854.x.

Abstract

OBJECTIVE

To study the influence of the position of the threads of an intrauterine contraceptive device (IUCD) on the development of genital tract infection.

DESIGN

A multicentre randomized controlled trial.

SUBJECTS

Women requesting an IUCD.

INTERVENTIONS

The women were randomized to be fitted with an IUCD either with the threads contained in the uterine cavity (threads-up group) (n = 208) or passing through the cervix to the vagina in the usual way (threads-down group) (n = 237). Multiple centre study with follow-up at three months, 1 and 2 years. At the final visit 'missing' threads were retrieved using a disposable instrument (Retrievette).

MAIN OUTCOME MEASURES

The occurrence of infection in the lower or upper genital tract.

RESULTS

63 women in the threads-up group and 78 in the threads-down groups dropped out. Previous gynaecological infection was reported by 21 and 48 women in the threads-up and threads-down group, respectively (odds ratio 0.44, 95% CI 0.24 to 0.79), 21 and 53 subjects had signs of infection at gynaecological examination (odds ratio 0.39, 95% CI 0.21 to 0.69) and a wet-smear was pathological in 33 and 79 (odds ratio 0.38, 95% CI 0.23 to 0.61). In the threads-up group the vaginal pH was also lower at the final check up after 2 years. Spontaneous descent of the threads occurred in 11% of the threads-up group and in six women in the threads-down group the threads were in the cervix. In 93 women the threads were easily retrieved by means of the Retrievette, four women insisted on the threads remaining in the uterus and in 18 thread removal was performed under local or general anaesthesia.

CONCLUSIONS

Infectious complications in women using an IUCD are more frequent if the threads lead from the uterine cavity to the vagina. This problem can be reduced by inserting the threads so that they remain entirely within the uterine cavity, a feasible procedure now that an effective instrument for IUCD thread retrieval is available.

摘要

相似文献

4
Laparoscopic removal of translocated intrauterine contraceptives devices.腹腔镜下取出移位的宫内节育器。
Br J Obstet Gynaecol. 1982 Feb;89(2):163-5. doi: 10.1111/j.1471-0528.1982.tb04686.x.
6
A solution to the problem of "missing" IUD threads.
Acta Obstet Gynecol Scand. 1986;65(1):89-91. doi: 10.3109/00016348609158236.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验