Suppr超能文献

全景X线片中牙齿长度的测量。2:观察者的表现。

Measurements of tooth length in panoramic radiographs. 2: Observer performance.

作者信息

Thanyakarn C, Hansen K, Rohlin M

机构信息

Centre for Oral Health Sciences, Lund University, Malmö, Sweden.

出版信息

Dentomaxillofac Radiol. 1992 Feb;21(1):31-5. doi: 10.1259/dmfr.21.1.1397449.

Abstract

Observer performance in tooth-length measurements in panoramic radiography has been examined. Sixty-four teeth, evenly distributed between maxillary first molars, second premolars and mandibular first and second premolars, were fixed in plastic moulds. Each cast was radiographed with an Orthopantomograph, twice with steel balls indicating the cusps and apices of the teeth and once without them. One observer measured the radiographic tooth length twice in both radiographs with indicators in order to estimate the true radiographic tooth length and the repositioning error, and twice in the radiographs without indicators. Seven other observers measured the tooth length on the radiographs without indicators, twice applying their own criteria and twice using defined criteria. The accuracy of the tooth-length measurements was calculated by comparing the true radiographic tooth length with the measurements of the seven observers. The intra-observer variation was defined as the difference between two measurements on the same radiograph. The accuracy and the precision of the tooth-length measurements were highly influenced by the observer performance. The mean radiographic tooth length of the seven observers was closer to the true radiographic tooth length when the observers applied the defined criteria. The inter- and intra-observer variation was higher for the measurements of the maxillary teeth (0.3-1.9 mm) compared with the mandibular teeth (0.3-0.9 mm) for most observers. The highest intra-observer variation was found for the palatal root of the maxillary first molar. The intra-observer variation of four observers decreased somewhat when the defined criteria were used; for the other three observers, however, the variation increased.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

已对全景X线摄影中牙齿长度测量的观察者表现进行了研究。64颗牙齿均匀分布于上颌第一磨牙、第二前磨牙以及下颌第一和第二前磨牙,被固定在塑料模具中。每个模型用曲面体层X线机进行X线摄影,两次带有指示牙齿牙尖和根尖的钢珠,一次不带有钢珠。一名观察者在两张带有指示物的X线片中两次测量X线片上的牙齿长度,以估计真实的X线片牙齿长度和重新定位误差,并在没有指示物的X线片中测量两次。其他七名观察者在没有指示物的X线片上测量牙齿长度,两次应用他们自己的标准,两次使用既定标准。通过将真实的X线片牙齿长度与七名观察者的测量结果进行比较来计算牙齿长度测量的准确性。观察者内变异被定义为同一张X线片上两次测量之间的差异。牙齿长度测量的准确性和精确性受观察者表现的影响很大。当观察者应用既定标准时,七名观察者的平均X线片牙齿长度更接近真实的X线片牙齿长度。对于大多数观察者来说,上颌牙齿测量的观察者间和观察者内变异(0.3 - 1.9毫米)高于下颌牙齿(0.3 - 0.9毫米)。上颌第一磨牙腭根的观察者内变异最大。当使用既定标准时,四名观察者的观察者内变异有所降低;然而,对于其他三名观察者来说,变异增加了。(摘要截断于250字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验