Synthetic porcine secretion was labelled by the conjugation-labelling method of Bolton & Hunter, the lactoperoxidase method, the gaseous diffusion method, and the chloramine-T method. The chloramine-T technique was adapted as routine method. Ten mug (3.27 nmol) peptide was reacted with 5 mCi of Na125I at a concentration of chloramine-T of 1.3 mmol/l. Synthetic secretin was suitable for labelling for at least eight months when stored as dry matter in nitrogen-filled glass ampoules. Purification and separation of labelled from unlabelled hormone was carried out by gel-permeation chromatography on Sephadex G-50 superfine. The labelled preparation had a specific radioactivity of 405 +/- 33 muCi/nmol (mean +/- SEM., n = 9) and was unable for six days. 6-tyrosyl-secretin took more iodine compared to porcine synthetic secretin but had lower immunoreactivity with all antisera tested.

摘要

采用博尔顿与亨特的偶联标记法、乳过氧化物酶法、气体扩散法以及氯胺 - T 法对合成猪分泌素进行标记。氯胺 - T 技术被用作常规方法。10 微克(3.27 纳摩尔)肽与 5 毫居里的 Na125I 在氯胺 - T 浓度为 1.3 毫摩尔/升的条件下反应。合成促胰液素以干燥物质形式储存在充氮玻璃安瓿中时,适合标记至少八个月。通过在 Sephadex G - 50 超细凝胶上进行凝胶渗透色谱法对标记的激素与未标记的激素进行纯化和分离。标记制剂的比放射性为 405±33 微居里/纳摩尔(平均值±标准误,n = 9),并且在六天内保持稳定。与猪合成促胰液素相比,6 - 酪氨酰促胰液素摄取的碘更多,但与所有测试抗血清的免疫反应性较低。