Suppr超能文献

一种通过精确的晶体体积测量来确定每个不对称单元中大分子数量的新方法。

A novel method of determining the number of macromolecules per asymmetric unit from accurate crystal-volume measurements.

作者信息

Li Fang, Steitz Thomas A

机构信息

Department of Molecular Biophysics and Biochemistry, Yale University, 266 Whitney Avenue, New Haven, CT 06520-8114, USA.

出版信息

Acta Crystallogr D Biol Crystallogr. 2003 Oct;59(Pt 10):1793-6. doi: 10.1107/s0907444903016858. Epub 2003 Sep 19.

Abstract

Knowledge of the number of macromolecules per crystallographic asymmetric unit is frequently useful in the determination of crystal structures. A method has been developed to establish this number directly from measurements of the volume and macromolecular contents of a crystal. The volume of a crystal is determined by measuring the volume of solvent that it displaces in a fine capillary tube. The macromolecular mass contained in a crystal is measured by dissolving the crystal in a known amount of water or suitable buffer and then measuring the UV absorbance of the solution. The method has been tested successfully on three different crystals of known structures.

摘要

了解每个晶体学不对称单元中的大分子数量在晶体结构测定中常常很有用。已开发出一种方法,可直接根据对晶体体积和大分子含量的测量来确定这个数量。晶体的体积通过测量其在细毛细管中所排开的溶剂体积来确定。晶体中所含的大分子质量通过将晶体溶解在已知量的水或合适的缓冲液中,然后测量溶液的紫外吸光度来测定。该方法已在三种已知结构的不同晶体上成功测试。