Laidlaw D A H, Abbott A, Rosser D A
Vitreo-Retinal Unit, St Thomas's Hospital, Lambeth Palace Road London SE1 7EH, UK.
Br J Ophthalmol. 2003 Oct;87(10):1232-4. doi: 10.1136/bjo.87.10.1232.
BACKGROUND/AIM: The "compact reduced logMAR" (cRLM) chart is being developed as a logMAR alternative to the Snellen chart. It is closer spaced and has fewer letters per line than conventional logMAR charts. Information regarding the performance of such a chart in amblyopes and children is therefore required. This study aimed to investigate the performance of the cRLM chart in amblyopic children.
Timed test and retest measurements using two versions of each chart design were obtained on the amblyopic eye of 43 children. Using the methods of Bland and Altman the agreement, test-retest variability (95% confidence limits for agreement, TRV) and test time of the cRLM and the current clinical standard Snellen chart were compared to the gold standard ETDRS logMAR chart.
No systematic bias between chart designs was found. For line assignment scoring the respective TRVs were 0.20 logMAR, 0.20 logMAR, and 0.30 logMAR. Single letter scoring TRVs were cRLM (95% CL 0.17) logMAR, ETDRS (95% CL 0.14) logMAR, and Snellen (95% CL 0.29) logMAR. Median testing times were ETDRS 60 seconds, cRLM 40 seconds, Snellen 30 seconds.
The sensitivity to change of the cRLM equalled or approached that of the gold standard ETDRS and was at least 50% better than that of Snellen. This enhanced sensitivity to change was at the cost of only a 10 second time penalty compared to Snellen. The cRLM chart was approximately half the width of the ETDRS chart. The cRLM chart may represent a clinically acceptable compromise between the desire to obtain logMAR acuities of reasonable and known sensitivity to change, chart size, and testing time.
背景/目的:“紧凑简化对数最小分辨角”(cRLM)视力表正在被开发,以作为Snellen视力表的对数最小分辨角替代方案。它的各行间距更近,每行的字母比传统对数最小分辨角视力表更少。因此,需要有关这种视力表在弱视患者和儿童中表现的信息。本研究旨在调查cRLM视力表在弱视儿童中的表现。
对43名儿童的弱视眼使用每种视力表设计的两个版本进行定时测试和复测测量。采用Bland和Altman方法,将cRLM视力表与当前临床标准Snellen视力表的一致性、重测变异性(一致性的95%置信限,TRV)和测试时间与金标准ETDRS对数最小分辨角视力表进行比较。
未发现视力表设计之间存在系统偏差。对于行分配评分,各自的TRV分别为0.20对数最小分辨角、0.20对数最小分辨角和0.30对数最小分辨角。单字母评分的TRV分别为cRLM(95%CL 0.17)对数最小分辨角、ETDRS(95%CL 0.14)对数最小分辨角和Snellen(95%CL 0.29)对数最小分辨角。测试时间中位数分别为ETDRS 60秒、cRLM 40秒、Snellen 30秒。
cRLM视力表对变化的敏感度等于或接近金标准ETDRS视力表,并且比Snellen视力表至少高50%。与Snellen视力表相比,这种对变化的更高敏感度仅以增加10秒测试时间为代价。cRLM视力表的宽度约为ETDRS视力表的一半。cRLM视力表可能代表了在获得具有合理且已知变化敏感度的对数最小分辨角视力、视力表大小和测试时间之间的临床可接受的折衷方案。