Suppr超能文献

时空图像相关技术(STIC):评估胎儿心脏的新技术。

Spatio-temporal image correlation (STIC): new technology for evaluation of the fetal heart.

作者信息

DeVore G R, Falkensammer P, Sklansky M S, Platt L D

机构信息

Fetal Diagnostic Center of Pasadena, Pasadena, CA 91105, USA.

出版信息

Ultrasound Obstet Gynecol. 2003 Oct;22(4):380-7. doi: 10.1002/uog.217.

Abstract

Spatio-temporal image correlation (STIC) is a new approach for clinical assessment of the fetal heart. It offers an easy to use technique to acquire data from the fetal heart and to aid in visualization with both two-dimensional and three-dimensional (3D) cine sequences. The acquisition is performed in two steps: first, images are acquired by a single, automatic volume sweep. Second, the system analyzes the image data according to their spatial and temporal domain and processes an online dynamic 3D image sequence that is displayed in a multiplanar reformatted cross-sectional display and/or a surface rendered display. The examiner can navigate within the heart, re-slice, and produce all of the standard image planes necessary for a comprehensive diagnosis. The advantages of STIC for use in evaluation of the fetal heart are as follows: the technique delivers a temporal resolution which corresponds to a B-mode frame rate of approximately 80 frames/s; it provides the examiner with an unlimited number of images for review; it allows for correlation between image planes that are perpendicular to the main image acquisition plane; it may shorten the evaluation time when complex heart defects are suspected; it enables the reconstruction of a 3D rendered image that contains depth and volume which may provide additional information that is not available from the thin multiplanar image slices (e.g. for pulmonary veins, septal thickness); it lends itself to storage and review of volume data by the examiner or by experts at a remote site; it provides the examiner with the ability to review all images in a looped cine sequence.

摘要

时空图像相关技术(STIC)是一种用于胎儿心脏临床评估的新方法。它提供了一种易于使用的技术,可从胎儿心脏获取数据,并通过二维和三维(3D)电影序列辅助可视化。采集过程分两步进行:首先,通过单次自动容积扫描采集图像。其次,系统根据图像数据的空间和时间域进行分析,并处理一个在线动态3D图像序列,该序列以多平面重新格式化的横截面显示和/或表面渲染显示方式呈现。检查者可以在心脏内部导航、重新切片,并生成全面诊断所需的所有标准图像平面。STIC用于评估胎儿心脏的优点如下:该技术提供的时间分辨率相当于约80帧/秒的B模式帧率;它为检查者提供了无限数量的图像以供查看;它允许在垂直于主要图像采集平面的图像平面之间进行关联;当怀疑有复杂心脏缺陷时,它可能会缩短评估时间;它能够重建包含深度和容积的3D渲染图像,这可能提供从薄的多平面图像切片中无法获得的额外信息(例如肺静脉、间隔厚度);它便于检查者或远程站点的专家存储和查看容积数据;它使检查者能够以循环电影序列的方式查看所有图像。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验